9.
Tank Sizes (flow meter only) - This setting is used to determine what size tank the control is con-
nected to. The display will first show "GOLD" for two seconds and then display the tank size default.
Adjust the tank size with the "+" or "-" keys.
GOLD
Pressing the "Status" key will temporarily store the setting and move to the next programming step.
10. Defaults (flow meter only) - This setting allows the con-
trol to automatically determine what the values shall be
for salt dosage, cycle times, batch capacity, and total
capacity based on the "temporarily stored" values above.
The display will first show "dEFLtS" for two seconds and
then display "YES" or "NO", with "YES" being the default.
"YES" and "NO" are toggled with the "+" or "-" keys.
If 'YES' is chosen, then pressing the "STATUS" key will let
the control automatically lookup, calculate, and save the
values for salt dosage, cycle times, batch capacity, and total
capacity, and proceed to the next item in the programming
menu.
If 'NO' is chosen, then the programmer will have the ability to set each value as desired for salt
dosage, cycle times, batch capacity, and total capacity. (Choosing "NO" will cancel Efficiency Mode if
it was active prior to this step)
11. View - This setting is used to allow the programmer to
view the calculated and looked up values for salt dosage,
cycle times, batch capacity, and total capacity. These val-
ues may only be viewed and can't be changed at this time.
This 'View' programming item is only available in the
menu if 'dEFLtS' was set to 'YES'. The display will show
"VIEW N". The "Y" or "N" will be toggled with the "+"
and "-" keys. The default for this item shall always be "N" and does not get saved in EEPROM. The
programmer must always toggle to "Y" in order to view these items.
If "Y" is chosen, then pressing the "STATUS" key will display the value for salt dosage; repeated press-
es of the status key will display cycle times, batch capacity, and total capacity.
Pressing the "STATUS" key after viewing "Maxcap" will exit the programming menu.
If "N" is chosen, then pressing the "STATUS" key will exit the programming menu.
12. Salt Dosage - This setting is used to set the salt dosage. The display will first show "dOSAGE" for two
seconds and then display the default (or previously programmed value). Adjust the salt dosage with
the "+" or "-" keys.
BOSA GE
9 X 48
BEFL E5
YES
VIEW N
LBS