Power Loss
The AccuSoft
®
circuit board is equipped with a Hi-Cap Capacitor and EEPROM memory chip.
The capacitor is capable of maintaining the time, for at least one day, in the event of a power
outage. The EEPROM ensures that the individual programming parameters of your softener are
not lost.
If the power outage lasts long enough to drain the Hi-Cap Capacitor, the control will flash
"12:00 PM" when power is returned to the control. The unit will continue to keep time from
the moment power is restored, and will initiate a full regeneration at the preset regeneration
time. The time of day will need to be reset in order to return the regeneration to its preset time.
If you live in an area where power outages occur with a regular frequency, a battery backup
option is available for ensuring that the time of day is properly maintained. Contact your
Culligan Dealer for more information.
Status Key
Toggle Down (-)
Display
Back lit LCD display.
Status Key
Depress to enter and move through the programming steps.
Regeneration Key
Press and hold the key for five (5) seconds to initiate an immediate regeneration.
When pressed during programming the time of day or time of regeneration, this
key will allow the user to toggle between the hours and minutes setting of timing
program segments.
Statistics Key
Each time depressed, the Statistics key will display statistical information such as
flow rate or time of day.
Toggle Down Key
In the programming mode this key will move the user through the programming
function in a descending mode. If depressed for greater than three seconds, the
(-)
rate at which the display scrolls through data will increase.
Toggle Up Key
In the programming mode this key will move the user through the programming
(+)
function in an ascending mode. If depressed for greater than five seconds, the rate
at which the display scrolls through the data will increase. This key will also allow
the user to manually step through the cycles of regeneration.