• Please read through this manual in its entirety. Field Convertible Doors The Avantco CFD1RR and CFD1FF both ship with a right-hinged door design. If you would like to convert the reach-in to a left hinged door design, you must purchase the bottom hinge seperately...
Page 3
User Manual 7. Replace the bottom hinge with the new left hand bottom bracket. It is held on with 3 bolts. 8. At this point, you will need to adjust the top and bottom spring tensioners so the door will close properly.
User Manual Electrical • Please ensure that the required voltage is being supplied at all times. • The unit should be plugged into a grounded and properly-sized electrical outlet with appropriate over-current protection. Please refer to the electrical requirements on the unit’s nameplate. •...
User Manual Defrost System Refrigerator coils are kept below the freezing point (32 degrees Fahrenheit). During compressor down-time, the evaporator fan continues to circulate air through the evaporator coil. This air circulation raises the coil temperature above the freezing point, melting any accumulated frost. Run-off water is drained into the evaporator pan and evaporated.
800 number located on the serial number plate. Be sure to have serial number available when contacting service technicians. This warranty does not apply to, and Avantco is not responsible for, any warranty claims made on products sold or used outside of the United States.