User Manual Refrigerated Prep Tables Safety Warning DANGER – RISK OF FIRE OR EXPLOSION. FLAMMABLE REFRIGERANT USED. TO BE REPAIRED ONLY BY TRAINED SERVICE PERSONNEL. DO NOT PUNCTURE REFRIGERANT TUBING. PELIGRO – RRIESGO DE INCENDIO O EXPLOSION. REFRIGERANTE INFLAMABLE UTILIZADO. PARA SER REPARADO SOLAMENTE POR PERSONAL DE SERVICIO CALIFICADO.
User Manual Refrigerated Prep Tables Installation This unit is intended for use in a temperature-controlled environment less than 75 degrees Fahrenheit and 60% relative humidity. Malfunction due to improper conditions is not covered under warranty. IMPORTANT – Please Read Before Installation: •...
User Manual Refrigerated Prep Tables • Select a location away from heat and moisture-generating equipment. - Ambient temperatures above 75 degrees Fahrenheit may cause the compressor to malfunction. - Using this unit in consistent ambient temperatures above 75 degrees Fahrenheit will void the warranty. Any exposure to ambient temperatures of 90 degrees Fahrenheit or above will also void the warranty.
User Manual Refrigerated Prep Tables Defrost System: Refrigerator coils are kept below the freezing point (32 degrees Fahrenheit). During compressor downtime, the evaporator fan continues to circulate air through the evaporator coil. This air circulation raises the coil temperature above the freezing point, melting any accumulated frost. Run-off water is drained into the evaporator pan and evaporated.
User Manual Refrigerated Prep Tables Operation / Maintenance WARNING DISCONNECT THE POWER CORD BEFORE CLEANING ANY PARTS OF THE UNIT. NOTE: We strongly recommend that any servicing be performed by an authorized service technician. Loading Product • Make sure there is at lease four inches of clearance from the evaporator. •...
User Manual Refrigerated Prep Tables Condenser Coil Cleaning Instructions: A dusty condenser may lead to high energy consumption, less cooling effectiveness, and compressor damage. The condenser coil is located at the bottom behind the panel. 1. Disconnect the electrical power from the unit. 2.
User Manual Refrigerated Prep Tables Troubleshooting Problem Possible Solution Fuse blown or circuit breaker tripped Replace fuse or reset circuit breaker Power cord unplugged Plug in power cord Compressor is Not Running Thermostat set too high Set thermostat to lower temperature Cabinet in defrost cycle Wait for defrost cycle to finish Thermostat is set too high...
Page 16
User Manual Refrigerated Prep Tables Troubleshooting Problem Possible Solution Excessive amount of warm product placed in cabinet Allow adequate time for product to cool down Prolonged door opening or door ajar Ensure doors are closed when not in use Avoid opening doors for long periods of time Door gasket(s) not sealing peroperly Condensing Units Run Ensure gaskets are snapped in completely...