Setting Recording Rate; Turning Functions On/Off; Owncal Calorie Counter On/Off; Fitness Test On/Off - Polar Electro S610 User Manual

Hide thumbs Also See for S610:
Table of Contents

Advertisement

Setting Recording Rate

You can program your receiver to record data in 5, 15 or 60 seconds
intervals.
1. In the Time of Day display scroll up or down
until OPTIONS is displayed.
2. Press OK to enter the Options mode.
EXERCISE SET is displayed.
3. Scroll up or down until MEMORY SET is
displayed.
4. Press OK to start the memory settings. Rec. Rate is displayed.
5. Scroll up or down to select the desired recording rate. As you change
the recording rate you can see the memory there is left in the lower
row. Press OK.
The recording time of the receiver depends on the selected recording rate
(5 s, 15 s, or 60 s). When the memory is full, you can continue exercising
but the exercise is no longer recorded. The following table shows the
maximum exercise times for each recording rate.
Recording rate
Maximum exercising time
5 s
22 h 03 min
15 s
66 h 10 min
60 s
99 h 59 min one file and total 260h
To continue your settings, press the stop button. To return to the Time of
Day display, press and hold the stop button.
Options
Memory Set
Rec. Rate 5 Sec / 15 Sec / 60 Sec
B 28

Turning Functions on/off

1. In the Time of Day display scroll
up or down until OPTIONS is
displayed.
2. Press OK to enter the Options
mode. EXERCISE SET is displayed.
3. Scroll up or down until FUNCTION SET is displayed.
4. Press OK to start the function settings. OwnCal is displayed.
To set the following functions on you have to set your user information.
If kg/lbs are displayed as you start setting the function on, the wrist
receiver points out that you have not set your all user information.

OwnCal Calorie Counter on/off

If you start from Time of Day display, repeat steps 1-4.
5. Press OK to start setting the OwnCal function. On/OFF starts to flash.
6. Scroll up or down to set the OwnCal on or off. Press OK.
To get the most accurate OwnCal results, update the VO
HR
setting with clinically measured values (if available). If you do not
max
know your clinically measured values perform Polar Fitness Test and update
the OwnIndex and HR
-p settings in Fitness Test mode.
max

Fitness Test on/off

If you start from Time of Day display, repeat steps 1-4.
5. Scroll up or down until Fit. Test is displayed.
6. Press OK to start setting the Fitness Test. On/OFF starts to flash.
7. Scroll up or down to set the Fitness Test on or off. Press OK.
B 29
Options
Function Set
OwnCal On/OFF
Fit. Test On/OFF
HR
-p On/OFF
max
setting and the
2max

Advertisement

Table of Contents
loading

This manual is also suitable for:

S610i

Table of Contents