4 Changing Oil:
Identify your pump from the figures on the adjacent page.
Remove the oil fill cap and the oil drain plug(s).
Dispose of spent oil as per local regulations.
Reinstall the drain plug(s). Torque to 18 lb-ft (hand tight). Do not over tighten.
Add recommended amount of oil to crankcase. Refer to the chart below for oil capacities.
Ensure that oil reaches the center of sight glass. Do not overfill.
Reinstall the oil fill cap.
Press the reset rocker switch inside the pump controller to reset the counter and shutoff the
service indicator.
Pump Model
Giant P205REIB
Giant P208REIB
Giant P217REIB
Giant P218REIB
Giant P219REIB
Giant P220REIB
Giant P56W
Giant P420A
- Synthetic 75w-90 grade oil is recommended for all applications (Mobile1 or equivalent).
- Synthetic 15w-50 grade oil can be used as an alternate grade. (Mobile1 or equivalent).
Incorrect oil grades can cause pump damage. Damage resulting from incorrect oil grades is
considered misuse and is not covered by warranty.
Table 3: Crankcase Oil Capacity
Oil Capacity - Do Not Overfill
9 fl. oz
9 fl. oz
9 fl. oz
9 fl. oz
9 fl. oz
9 fl. oz
14 fl. oz
30 fl. oz
HP Series Installation Manual | 40