B. Facing Material
Cover the metal front faces with non-combustible materi-
als only.
Facing and/or fi nishing materials must not interfere with
air fl ow through louvers, operation of louvers or doors,
or access for service.
Facing and/or fi nishing materials must never overhang
into the glass opening.
Observe all clearances when applying combustible
materials.
Seal joints between the fi nished wall and appliance top
and sides using a 300 °F minimum sealant. Refer to
Figure 14.3.
WARNING! Risk of Fire! DO NOT apply combustible
materials beyond the minimum clearances. Comply with
all minimum clearances to combustibles as specifi ed in
this manual. Overlapping materials could ignite and will
interfere with proper operation of doors and louvers.
Finish wall material may be
combustible - Top and Sides
0 in.
High Temperature Sealant (300° F/149° C min.)
Top and Side Seal Joint
Figure 14.3 Non-combustible Facing Diagram
54
0 in.
0 in.
Heatilator • Novus NDV Series • 4055-187 Rev. AA • 10/13