Advertisement

Model(s):
NDV3630, NDV3933, NDV4236, NDV4842,
NDV3630I, NDV3933I, NDV4236I, NDV4842I,
NDV3630L, NDV3933L, NDV4236L, NDV4842L,
NDV3036IL, NDV3933IL, NDV4236IL, NDV4842IL
WARNING: If the information in these
or explosion may result causing property
damage, personal injury, or death.
• DO NOT
• What to do if you smell gas
- DO NOT
- DO NOT
NOT
Title 24 CFR, Part 3280 or Standard for Installation in Mobile
Homes, CAN/CSA Z240MH, in Canada .
This appliance is only for use with the type(s) of gas indicated
on the rating plate.
NOTICE
DO NOT DISCARD THIS MANUAL
-
DO
-
Heatilator • Novus NDV Series • 4055-187 Rev J • 08/09
Owner's Manual
WARNING
HOT SURFACES!
Hot glass will cause burns.
DO NOT
materials.
This appliance has been supplied with an integral barrier
Installation and Operation
1

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the NDV3630 and is the answer not in the manual?

Questions and answers

Summary of Contents for Heatilator NDV3630

  • Page 1 Title 24 CFR, Part 3280 or Standard for Installation in Mobile Homes, CAN/CSA Z240MH, in Canada . This appliance is only for use with the type(s) of gas indicated on the rating plate. Heatilator • Novus NDV Series • 4055-187 Rev J • 08/09...
  • Page 2 DO NOT REMOVE OR COVER THIS LABEL. VENTED GAS FIREPLACE - NOT FOR USE WITH SOLID FUEL. FOYER À GAZ À ÉVACUATION - NE DOIT PAS ÊTRE UTILISÉ AVEC UN COMBUSTIBLE SOLIDE. Heatilator • Novus NDV Series • 4055-187 Rev J • 08/09...
  • Page 3: Table Of Contents

    2 Operating Instructions 10 Installing Vent Pipe 11 Shrouds 3 Maintenance and Service 12 Gas Information Installer Guide 4 Getting Started 13 Electrical Information 5 Framing and Clearances 6 Termination Locations Heatilator • Novus NDV Series • 4055-187 Rev J • 08/09...
  • Page 4 14 Finishing 15 Appliance Setup 16 Troubleshooting 17 Reference Materials Heatilator • Novus NDV Series • 4055-187 Rev J • 08/09...
  • Page 5 Adjustments, regular maintenance, cleaning and temporary repairs, or the failure to duplicate the problem in the home is not covered under this warranty. 4021-645A 09-01-08 Page 1 of 2 Heatilator • Novus NDV Series • 4055-187 Rev J • 08/09...
  • Page 6 If warranty service is needed, you should contact your installing dealer. If the installing dealer is unable to provide neces- sary parts or components, contact the nearest authorized HHT dealer or supplier. 4021-645A 09-01-08 Page 2 of 2 Heatilator • Novus NDV Series • 4055-187 Rev J • 08/09...
  • Page 7: Listing And Code Approvals

    This appliance must be electrically wired and grounded in accordance with local codes or, in the absence of local codes, with National Electric Code ANSI/NFPA 70-latest edition or the Canadian Electric Code CSA C22.1. Heatilator • Novus NDV Series • 4055-187 Rev J • 08/09...
  • Page 8 Gas Equipment Venting System NOT Provided Approved Carbon Monoxide Detectors Signage “GAS VENT DIRECTLY BELOW. KEEP CLEAR OF ALL OB- STRUCTIONS”. See Gas Connection section for additional Common- Inspection wealth of Massachusetts requirements. Heatilator • Novus NDV Series • 4055-187 Rev J • 08/09...
  • Page 9: Operating Instructions

    B. Your Fireplace Failure to DECORATIVE DOORS (NOT SHOWN) SECTION 2 MANTEL FIXED GLASS ASSEMBLY SECTION 14 HEARTH CLEAR SPACE (not required) SECTION 2 Figure 2.1 General Operating Parts Heatilator • Novus NDV Series • 4055-187 Rev J • 08/09...
  • Page 10 Hearth & Home Technologies. Unapproved doors or fronts may cause appliance to overheat. This appliance has been supplied with an integral barrier Red or Black Button Figure 2.3 Ignitor Button Heatilator • Novus NDV Series • 4055-187 Rev J • 08/09...
  • Page 11 I. Intermittent Pilot Ignition (IPI) Heatilator • Novus NDV Series • 4055-187 Rev J • 08/09...
  • Page 12 J. Standing Pilot Ignition Heatilator • Novus NDV Series • 4055-187 Rev J • 08/09...
  • Page 13 • Smoke detectors may activate. Figure 2.4 DEXEN Valve - IntelliFire Ignition System Indicator L. Flame Adjustment Control Figure 2.5 SIT Valve - Standing Pilot Ignition System M. Frequently Asked Questions ISSUE SOLUTIONS Heatilator • Novus NDV Series • 4055-187 Rev J • 08/09...
  • Page 14: Maintenance And Service

    Glass Cleaning Frequency: Tools Needed Glass is breakable. • Avoid striking, scratching or slamming glass • Avoid abrasive cleaners • clean glass while it is hot • Note • • Heatilator • Novus NDV Series • 4055-187 Rev J • 08/09...
  • Page 15 B. Maintenance Tasks-Service Technician Gasket Seal and Glass Assembly Inspection Frequency: DO NOT Tools needed: Logs Frequency: Tools needed: Firebox Frequency: Tools needed: Control Compartment and Firebox Top Frequency: Heatilator • Novus NDV Series • 4055-187 Rev J • 08/09...
  • Page 16 Figure 3.1 IPI Flame Patterns Figure 3.2 Standing Pilot Flame Patterns Heatilator • Novus NDV Series • 4055-187 Rev J • 08/09...
  • Page 17: Getting Started

    OPTIONAL WALL SWITCH (Section 12) MANTEL AND MANTEL LEG (SECTION 5 & 13) SURROUND (SECTION 14) HEARTH EXTENSION (Section 13) GAS LINE (SECTION 11) Figure 4.1 Typical Appliance System Heatilator • Novus NDV Series • 4055-187 Rev J • 08/09...
  • Page 18 C. Tools and Supplies Needed use this appliance if any part has been under water. replace any part of the control system and/or gas control which has been under water. Heatilator • Novus NDV Series • 4055-187 Rev J • 08/09...
  • Page 19: Framing And Clearances

    1102 1194 1353 1016 NDV4236 37-5/8 19-5/8 43-3/8 53-1/4 1067 1102 1194 1353 1092 NDV4842 41-7/8 19-5/8 43-3/8 53-1/4 1219 1064 1102 1194 1353 1245 Figure 5.1 Appliance Locations Heatilator • Novus NDV Series • 4055-187 Rev J • 08/09...
  • Page 20 19-5/8 in./498 mm 10 in./254 mm 9 in./229 mm NDV4842 48 in./1219 mm 34-7/8 in./886 mm 19-5/8 in./498 mm 10 in./254 mm 9 in./229 mm Figure 5.2 Clearances to Combustibles Heatilator • Novus NDV Series • 4055-187 Rev J • 08/09...
  • Page 21 Mantel Leg or Wall Projections (Acceptable on both 6-1/4 5-1/2 sides of opening) Measured from top of hood (in inches) Figure 5.3 Clearances To Mantels Or Other Combustibles Above Appliance Heatilator • Novus NDV Series • 4055-187 Rev J • 08/09...
  • Page 22: Termination Locations

    Over 18/12 to 20/12 Over 10/12 to 11/12 3.25 Over 20/12 to 21/12 * 3 ft. minimum in snow regions Figure 6.1 Minimum Height From Roof To Lowest Discharge Opening Heatilator • Novus NDV Series • 4055-187 Rev J • 08/09...
  • Page 23 Applications from this surface. Figure 6.3 Minimum Clearances for Terminations CAUTION: IF EXTERIOR WALLS ARE FINISHED WITH VINYL SIDING, IT IS SUGGESTED THAT A VINYL PROTECTOR KIT BE INSTALLED. Heatilator • Novus NDV Series • 4055-187 Rev J • 08/09...
  • Page 24: Vent Information And Diagrams

    SLP6A 2 - 6 51 - 152 SLP Pipe SLP12A 2 - 12 51 - 305 (see chart) Figure 7.2 Pipe Effective Length Vertical 8-1/2 in. Horizontal Figure 7.1 Heatilator • Novus NDV Series • 4055-187 Rev J • 08/09...
  • Page 25 Adapter 12 ft (3.66 m) min. 12 ft (3.66 m) min. 60 ft (18.29 m) max. 60 ft (18.29 m) max. Figure 7.3 Minimum Installation Requirements for Two 45° Heatilator • Novus NDV Series • 4055-187 Rev J • 08/09...
  • Page 26 Max. One Elbow Figure 7.4 Two Elbows min. max. max. H max. measurement measurement Installed Vertically Installed Horizontally Figure 7.5 Heatilator • Novus NDV Series • 4055-187 Rev J • 08/09...
  • Page 27 - (continued) min. max. max. Three Elbows Installed Vertically Figure 7.6 Heatilator • Novus NDV Series • 4055-187 Rev J • 08/09...
  • Page 28 60 ft (18.29 m) max. Maximum horizontal run is 100% of vertical, but cannot exceed 26 ft (7.92 m) Figure 7.7d 31 ft to 60 ft Vertical Run Figure 7.8 Heatilator • Novus NDV Series • 4055-187 Rev J • 08/09...
  • Page 29 Three Elbows measurement measurement Maximum horizontal run is 100% of vertical, but cannot exceed 26 ft (7.92 m) 12 ft (3.66 m) min. 60 ft (18.29 m) max. Figure 7.9 Heatilator • Novus NDV Series • 4055-187 Rev J • 08/09...
  • Page 30 No Elbow 18 in. (457 mm) max. Figure 7.10 One 45° Elbow 18 in. (457 mm) max. Figure 7.11 Heatilator • Novus NDV Series • 4055-187 Rev J • 08/09...
  • Page 31 Total Vert Two Elbows Model V Min. Series Figure 7.12 Total Vert V Three Elbows Model H1 Max Min. Series measurement measurement Installed Horizontally Figure 7.13 Heatilator • Novus NDV Series • 4055-187 Rev J • 08/09...
  • Page 32 12 ft (3.66 m) min. 6 ft (1.83 m) max. 60 ft (18.29 m) max. Maximum horizontal run is 100% of vertical, but cannot exceed 26 ft (7.92 m) Figure 7.15 Heatilator • Novus NDV Series • 4055-187 Rev J • 08/09...
  • Page 33 6 ft (1.83 m) max. 12 ft (3.66 m) min. 60 ft (18.29 m) max. Maximum horizontal run is 100% of vertical, but can- not exceed 26 ft (7.92 m). Figure 7.16 Heatilator • Novus NDV Series • 4055-187 Rev J • 08/09...
  • Page 34: Vent Clearances And Framing

    Top: 2-1/2 in. (64 mm) Bottom: 1/2 in. (13 mm) Sides: 1 in. (25 mm) Figure 8.1 Pipe Clearances Figure 8.2 Wall Penetration DVP only Heatilator • Novus NDV Series • 4055-187 Rev J • 08/09...
  • Page 35 INSTALL ATTIC INSULATION SHIELDS BEFORE OR AFTER INSTALLATION OF VENT SYSTEM 3 FASTENERS PER SIDE CEILING FIRESTOP CEILING FIRESTOP INSTALLED BELOW CEILING INSTALLED ABOVE CEILING Figure 8.4 Installing the Attic Shield Heatilator • Novus NDV Series • 4055-187 Rev J • 08/09...
  • Page 36 90° from falling inside to maintain clearance Note: Figure 8.5 Attic Insulation Shield Vaulted Ceiling Installation Cut previously installed batt insulation to make room for the attic insulation shield. Heatilator • Novus NDV Series • 4055-187 Rev J • 08/09...
  • Page 37: Appliance Preparation

    Once appliance is set up for top or rear venting, it CANNOT be changed at a later time. Figure 9.4 Figure 9.1 Figure 9.5 Figure 9.2 Figure 9.6 Figure 9.3 Proceed to Section 10. C. Heatilator • Novus NDV Series • 4055-187 Rev J • 08/09...
  • Page 38 Once appliance is set up for top or rear venting, be reattached. it CANNOT be changed at a later time. Figure 9.7 Figure 9.10 Figure 9.8 Figure 9.11 Figure 9.9 Heatilator • Novus NDV Series • 4055-187 Rev J • 08/09...
  • Page 39 Failure to maintain air space clearance may cause Nailing Flanges (both sides) Figure 9.12 Proper Positioning, Leveling And Securing of an Ap- pliance Heatilator • Novus NDV Series • 4055-187 Rev J • 08/09...
  • Page 40: Installing Vent Pipe

    If slip section seals are broken during removal of the termination cap, vent will Figure 10.3 Figure 10.2 Assemble Pipe Sections Note: CORRECT DO NOT INCORRECT Figure 10.4 Seams Heatilator • Novus NDV Series • 4055-187 Rev J • 08/09...
  • Page 41 • Apply a bead of silicone sealant inside the female outer pipe joint prior to joining sections. • required. • shall be sealed. Heatilator • Novus NDV Series • 4055-187 Rev J • 08/09...
  • Page 42 Figure 10.10 Rotate Seams for Disassembly Figure 10.11 Align and Disassemble Vent Sections Figure 10.8 Securing Vertical Pipe Sections Heatilator • Novus NDV Series • 4055-187 Rev J • 08/09...
  • Page 43 Cut hole 1/8 in. (3 mm) greater in size than pattern of support box as it is projected onto roofline. Figure 10.12 Clean out ALL materials from Figure 10.13 and termination. Heatilator • Novus NDV Series • 4055-187 Rev J • 08/09...
  • Page 44 Figure 10.14 Minimum Height From Roof To Lowest Discharge Figure 10.16 Assembling the Storm Collar Opening cause water entry. Pipe Caulk Figure 10.17 Assembling the Storm Collar Around the Pipe Flashing Figure 10.15 Heatilator • Novus NDV Series • 4055-187 Rev J • 08/09...
  • Page 45 • Heat shields must overlap 1-1/2 in. (38 mm) mini- mum. • Figure 10.18 J. Install Decorative Wall Components SLP only) Important Notice: Figure 10.19 Wall Thimble Heatilator • Novus NDV Series • 4055-187 Rev J • 08/09...
  • Page 46 SLP-TRAP2 can adjust 4 in. (5 1/4 to 9 1/4)) DVP-HPC1 can adjust 2 1/8 in. (4 1/4 to 6 3/8) DVP-HPC2 can adjust 4 1/8 in. (6 3/8 to 10 1/2) Heatilator • Novus NDV Series • 4055-187 Rev J • 08/09...
  • Page 47: Shrouds

    Open Top Shroud (may be used with DVP-TV, DVP-TVHW, SLP-TVHW) Min. Base Dims. Min. Top Dim. Min. Top Dim. Min. Top Dims. Min. Base Dim. Min. Base Dim. Figure 11.1 Open Top Shroud Dimensions Heatilator • Novus NDV Series • 4055-187 Rev J • 08/09...
  • Page 48 Roofed Style Shroud (may be used with DVP-TV, DVP-TVHW, SLP-TVHW) Min. Base Dims. Min. Height Minimum Height Minimum Opening Min. Opening Width Height Min. Opening Width Minimum Base Dimension Min. Opening Height Figure 11.2 Roofed Style Shroud Dimensions Heatilator • Novus NDV Series • 4055-187 Rev J • 08/09...
  • Page 49: Gas Information

    Check with your local gas utility or authorities having jurisdiction. Note: Note: • If substituting for these components, please consult local codes for compliance. Heatilator • Novus NDV Series • 4055-187 Rev J • 08/09...
  • Page 50: Electrical Information

    Battery polarity must be correct or module Red or Black damage will occur. Button D. Optional Accessories Requirements Figure 13.1 Ignitor Button Heatilator • Novus NDV Series • 4055-187 Rev J • 08/09...
  • Page 51 Figure 13.2 Standing Pilot Ignition Wiring Diagram Ignitor Flame Sensor Battery * GRN wire only used Pack with optional wall switch Pilot Assembly WSK-MLT-HTL Control Junction Wall Switch Adapter GRN* Valve Heatilator • Novus NDV Series • 4055-187 Rev J • 08/09...
  • Page 52 Minimum 14-3 AWG with Ground Black Black White White Green Green Junction Box Power Switch Box Supply Wires Knockout Figure 13.5 Junction Box Wired to Wall Switch or BC10 Heatilator • Novus NDV Series • 4055-187 Rev J • 08/09...
  • Page 53 1 in. (25 mm) min. to perpendicular wall 3-1/2 in. (89 mm) min. from fireplace opening to perpendicular wall Figure 14.2 Mantel Leg or Wall Projections (Acceptable on both sides of opening) Heatilator • Novus NDV Series • 4055-187 Rev J • 08/09...
  • Page 54 Finish wall material may be combustible - Top and Sides 0 in. 0 in. 0 in. High Temperature Sealant (300° F/149° C min.) Top and Side Seal Joint Figure 14.3 Non-combustible Facing Diagram Heatilator • Novus NDV Series • 4055-187 Rev J • 08/09...
  • Page 55: Appliance Setup

    Hearth & Home Technologies-approved optional acces- sories with this appliance. Using non-listed accessories could result in a safety hazad and will void the warranty. Figure 15.3 Remove Screen Package Heatilator • Novus NDV Series • 4055-187 Rev J • 08/09...
  • Page 56 Open Rockwool Figure 15.6 Adjusting Air Shutter Lava Rock & Vermiculite Figure 15.5 Placement of Rockwool, Lava Rock and Vermiculite I. Place the Vermiculite J. Replacing Fixed Glass Assembly Heatilator • Novus NDV Series • 4055-187 Rev J • 08/09...
  • Page 57 Figure 15.10 Intalling Hood O. Install Floor Cover Figure 15.8 Remove Screen Protector M. Unpackage the Hood & Floor Cover Figure 15.11 Installing Floor Cover Note: Figure 15.9 Removing Parts Package Heatilator • Novus NDV Series • 4055-187 Rev J • 08/09...
  • Page 58 Open Figure 15.14 Rotate the Screen Down Figure 15.12 Magnetic Touch Latch Open Hang Screen on Shoulder Screws Figure 15.15 Press on Bottom of Screen Figure 15.13 Hang Screen Heatilator • Novus NDV Series • 4055-187 Rev J • 08/09...
  • Page 59: Troubleshooting

    Troubleshooting A. Standing Pilot Ignition System Symptom Possible Causes Corrective Action Heatilator • Novus NDV Series • 4055-187 Rev J • 08/09...
  • Page 60 Troubleshooting (continued) Symptom Possible Cause Corrective Action Heatilator • Novus NDV Series • 4055-187 Rev J • 08/09...
  • Page 61 Symptom Possible Cause Corrective Action Heatilator • Novus NDV Series • 4055-187 Rev J • 08/09...
  • Page 62 Symptom Possible Cause Corrective Action Heatilator • Novus NDV Series • 4055-187 Rev J • 08/09...
  • Page 63: Reference Materials

    (203 mm) 15-3/4 in. (400 mm) 23-1/2 in. (597 mm) Model NDV3630 8 5/8 NDV3933 11 5/8 NDV4236 14 5/8 1041 NDV4842 20 5/8 1194 1067 Figure 17.1 Appliance Dimensions Heatilator • Novus NDV Series • 4055-187 Rev J • 08/09...
  • Page 64 (254 mm) 8 in. (203 mm) 14 in. (356 mm) 12 in. (305 mm) 5 in. (127 mm) DVP-WS DVP-HVS Wall Shield Firestop Vent Support Figure 17.2 DVP Vent Components Heatilator • Novus NDV Series • 4055-187 Rev J • 08/09...
  • Page 65 Flashing 13-7/8 in. 9-1/2 in. (352 mm) (241 mm) 26 in. (660 mm) 14 in. (356 mm) DVP-HSM-B Extended Heat Shield DRC-RADIUS Cap Shield Figure 17.3 DVP Vent Components Heatilator • Novus NDV Series • 4055-187 Rev J • 08/09...
  • Page 66 7-1/8 in. 12-1/8 in. Fire Brick Termination Cap (181 mm) (314 mm) 8-3/4 in. (222 mm) 1-5/8 in. (41 mm) DVP-HPC High Performance Cap Figure 17.4 DVP Vent Components Heatilator • Novus NDV Series • 4055-187 Rev J • 08/09...
  • Page 67 12 in. 5-3/8 in. 9-3/8 in. Trap2 Effective (305 mm) 137 mm 238 mm Length DVP-TRAP Horizontal Termination Cap DVP-TRAP1 DVP-TRAPK1 DVP-TRAP2 DVP-TRAPK2 DVP-HPC1 DVP-HPC2 Figure 17.5 DVP Vent Components Heatilator • Novus NDV Series • 4055-187 Rev J • 08/09...
  • Page 68 5-3/4 to 8-3/8 in. 140 mm 213 mm 146 to 213 mm 3° 87° 10-1/2 in. 267 mm 10-7/8 in. 276 mm DVP-HRC-ZC-SS (Not approved for NDV4842) Figure 17.6 DVP Vent Components Heatilator • Novus NDV Series • 4055-187 Rev J • 08/09...
  • Page 69 2 - 12 51 - 305 SLP-DCF-BK SLP-WT-BK SLP-FS SLP-WS Ceiling Firestop-Black Wall Thimble-Black Ceiling Firestop Wall Shield Firestop 26 in. (660 mm) SLP-HVS Support Figure 17.7 SLP Series Vent Components Heatilator • Novus NDV Series • 4055-187 Rev J • 08/09...
  • Page 70 213 mm 146 to 213 mm 3° 87° 10-1/2 in. 267 mm 10-7/8 in. 276 mm SLP-HRC-ZC-SS SLP-TRAP2 (Not approved for NDV4842) Termination Cap Figure 17.8 SLP Series Vent Components Heatilator • Novus NDV Series • 4055-187 Rev J • 08/09...
  • Page 71 121 mm 12 in. 5 1/4 in. 9 1/4 in. Trap2 Effective (305 mm) 133 mm 235 mm Length SLP-TRAP Horizontal Termination Cap Figure 17.9 SLP Series Vent Components Heatilator • Novus NDV Series • 4055-187 Rev J • 08/09...
  • Page 72 C. Service Parts Heatilator • Novus NDV Series • 4055-187 Rev J • 08/09...
  • Page 73 C. Service Parts (continued) Heatilator • Novus NDV Series • 4055-187 Rev J • 08/09...
  • Page 74 C. Service Parts (continued) Heatilator • Novus NDV Series • 4055-187 Rev J • 08/09...
  • Page 75 C. Service Parts (continued) Heatilator • Novus NDV Series • 4055-187 Rev J • 08/09...
  • Page 76 C. Service Parts (continued) Heatilator • Novus NDV Series • 4055-187 Rev J • 08/09...
  • Page 77 C. Service Parts (continued) Heatilator • Novus NDV Series • 4055-187 Rev J • 08/09...
  • Page 78 C. Service Parts (continued) Heatilator • Novus NDV Series • 4055-187 Rev J • 08/09...
  • Page 79 C. Service Parts (continued) Heatilator • Novus NDV Series • 4055-187 Rev J • 08/09...
  • Page 80 C. Service Parts (continued) Heatilator • Novus NDV Series • 4055-187 Rev J • 08/09...
  • Page 81 C. Service Parts (continued) Heatilator • Novus NDV Series • 4055-187 Rev J • 08/09...
  • Page 82 C. Service Parts (continued) Heatilator • Novus NDV Series • 4055-187 Rev J • 08/09...
  • Page 83 C. Service Parts (continued) Heatilator • Novus NDV Series • 4055-187 Rev J • 08/09...
  • Page 84 Description NDV3630 NDV3933 NDV3630L NDV3933L NDV3630I NDV3933I NDV3630IL NDV3933IL WTB30 WTB33 WHB30 WHB33 BC10 BC10 WSK300 WSK300 DCKVN DCKVN SCKVN-B Natural Gas Conversion Kit SCKVN-B Natural Gas Conversion Kit Heatilator • Novus NDV Series • 4055-187 Rev J • 08/09...
  • Page 85 Description NDV4236 NDV4842 NDV4236L NDV4842L NDV4236I NDV4842I NDV4236IL NDV4842IL WTB36 WTB42 WHB36 WHB42 BC10 BC10 WSK300 WSK300 DCKVN DCKVN SCKVN-B Natural Gas Conversion Kit SCKVN-B Natural Gas Conversion Kit Heatilator • Novus NDV Series • 4055-187 Rev J • 08/09...
  • Page 86 9-3/8 in. [238 mm] LDS33/LDS46 Decorative Shroud TCG375 Terra Cotta Cap Catalog # LDS33 LDS46 1219 1829 LDSCP-M Shroud Leg Multipack (not shown) LDS-BV Decorative Shroud Catalog # LDS-BV Heatilator • Novus NDV Series • 4055-187 Rev J • 08/09...
  • Page 87 Heatilator • Novus NDV Series • 4055-187 Rev J • 08/09...
  • Page 88 E. Contact Information www.heatilator.com - NOTES - ________________________________________________________________________________ ________________________________________________________________________________ ________________________________________________________________________________ ________________________________________________________________________________ ________________________________________________________________________________ ________________________________________________________________________________ ________________________________________________________________________________ ________________________________________________________________________________ ________________________________________________________________________________ NOTICE DO NOT DISCARD THIS MANUAL Printed in U.S.A. - Copyright 2006 Heatilator • Novus NDV Series • 4055-187 Rev J • 08/09...