6.0 Power Requirements

Jacuzzi
spas are designed to provide optimum performance and flex-
®
ibility of use when connected to the maximum electrical service listed in
the tables below. If you prefer, your dealer can perform a minor circuit
board modification to allow your spa to accept an electrical service other
than the factory setting.
US/Canada J-210 / J-220 1-Pump Convertible Model (60Hz)
Voltage:
# of Wires:
Frequency:
Current Draw:
Circuit Breaker:
For 240 VAC Heater Operation: Move the red wire on the main terminal
strip (TB) from position # to position #3. Make certain wires are con-
nected exactly as shown in Figure-D (page 3) before applying power.
Failure to do so will result in damage to the circuit board and/or related
components and void the manufacturer's warranty.
*All Canadian spas must be hard wired (120 VAC or 240 VAC) per
CSA Canadian standards. (page 4).
*
In 5A/30A configuration, the heater will not operate at the same
time as the high-speed jets pump. The factory setting is 120V/15A.
** In 40A configuration, remove the jumper JP #-2 on the circuit board
to allow the heater to operate at the same time as the
high-speed jets pump (page 33).
US/Canada J-230 2-Pump Model (60Hz)
Voltage:
# of Wires:
Frequency:
Current Draw:
Circuit Breaker:
*
In 40A configuration, the heater will not operate while either jets
pump is running in high speed. Note: pump 2 runs only in high speed.
** In 50A configuration, the heater will not operate while both jet pumps
are running in high speed. Note: pump 2 runs only in high speed.
This is the factory setting.
*** In 60A configuration, the heater will operate while both jet pumps are
running in high speed. Note: pump 2 runs only in high speed.
page 0
120V/15A*
20 VAC
3 (5A GFCI Cord
US only*)
60Hz
2A
5A, -Pole
240V/40A*
240 VAC
3
60Hz
26A
40A, 2-Pole
240V/30A*
240 VAC
4 (Hard
Wired only)
60Hz
2A
30A, 2-Pole
240V/50A**
240 VAC
3
60Hz
36A
50A, 2-Pole
240V/40A**
240 VAC
4 (Hard
Wired only)
60Hz
30A
40A, 2-Pole
240V/60A***
240 VAC
3
60Hz
45A
60A, 2-Pole

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

J-220J-230Led j-210Led j-220Led j-230

Table of Contents