To clean the canister filters:
1.
Move the canister handle back and forth to
free trapped dust particles from the filter
(Figure 25). The particles will fall into the col-
lection bag.
Figure 25. Move canister handle back and forth.
To empty the collection bag:
1.
Make sure you are wearing a repirator and
the dust collector is unplugged.
2.
When the collection bag is full, unclamp the
collection bag and dispose of the dust.
3.
Install a new collection bag.
While the Model G0562 excels at collecting the
majority of wood dust produced by your
machines, it is not an air filter; therefore, we
strongly recommend the supplemental aid of a
shop air filter such as the Grizzly G5955 or
G9956. Air filters are designed to collect the
smaller dust particles that dust collector bags
cannot trap.
-24-

Baffle Adjustment

If you notice that one dust collector bag is filling
up faster than the other, there is a flow problem
which should be corrected. This adjustment may
take some trial and error.
To adjust the baffle:
1.
Disconnect the machine from the power
source!
2.
Remove the canister, lower bag and collec-
tor from the side that is collecting the most
dust.
3.
Reach inside the metal intake and move the
baffle (Figure 26) toward you. Note—The
manifold flow adjustment piece is solid and
needs to be bent to allow for adjustment.
towards the opening of the bag that is col-
lecting the most dust to equalize the bag col-
lection.
Figure 26. Baffle adjustment piece.
4.
Assemble the components of the dust col-
lector removed in step 2.