B. Facing Material
Metal front faces may be covered with non-combustible
materials only.
Facing and/or fi nishing materials must not interfere with
air fl ow through louvers, operation of louvers or doors,
or access for service.
Facing and/or fi nishing materials must never overhang
into the glass opening.
Observe all clearances when applying combustible
materials.
Seal joints between the fi nished wall and appliance top
and sides using a 300 °F minimum sealant. Refer to
Figure 13.3.
WARNING! Risk of Fire! DO NOT apply combustible ma-
terials beyond the minimum clearances. Comply with all
minimum clearances to combustibles as specifi ed in this
manual. Overlapping materials could ignite and will inter-
fere with proper operation of doors and louvers.
Finish wall material may be
combustible - Top and Sides
0 in.
High Temperature Sealant (300° F/149° C min.)
Top and Side Seal Joint
Figure 13.3 Noncombustible Facing Diagram
0 in.
0 in.
Heatilator • AVEO Series DV • 4058-210 Rev F • 10/08