N0422, F0522, N0622, F0822, N0922, F1222, N1322, F1522
Air, Water or Remote User Manual

Water - Remote Models

The water supply for ice making must be cold,
potable water. There is a single
potable water connection on the back panel.
Backflow
The design of the float valve and reservoir prevents
potable water backflow by means of a 1" air gap
between the reservoir's maximum water level and
the float valve water inlet orifice.
Drain
There is one ¾" FPT condensate drain fitting at the
back of the cabinet.
Attach Tubing
Connect the potable water supply to the potable
water fitting,
3
" OD copper tubing or the
8
equivalent is
recommended.
Water filtration is
recommended. If
there is an
existing filter,
change the
cartridge.
" male flare
3
8
To Remote Condenser
Potable Water
Drain Vent
Condensate
Drain
July 2009
Page 14
Drains - use rigid tubing: Connect the drain tube to
the condensate drain fitting. Vent the drain.
Do not Tee ice machine drains into the drain tube
from the ice storage bin or dispenser. Back ups
could contaminate and / or melt the ice in the bin or
dispenser. Be sure to vent the bin drain.
Follow all local and national codes for tubing, traps
and air gaps.