150 PSI supply to the machine which contributes to this situation. Testing has shown that using a filter that Voltage limits does not remove chlorine, such as the Scotsman Aqua Patrol, will greatly improve this situation. Minimum Maximum Warranty Information...
Scotsman assumes no liability of responsibility of any kind for products Additionally the control system includes an manufactured by Scotsman that have been altered...
NB0622, NB0922, FB1222, NB1322 Installation and Use NB0622 Cabinet Layout 58.1 55.9 22.89 22.00 REF. 31.8 12.50 ULTRA SONIC BIN LEVEL SENSOR OPTIONAL [58.5] 23.00 PLAN VIEW 24.00 REF. 41.9 16.50 ICE DROP LOUVER AND OPENING 2.92 REMOVABLE FILTER A/C UNITS ONLY 55.9...
NB0622, NB0922, FB1222, NB1322 Installation and Use NB0922, FB1222, NB1322 Cabinet Layout 55.9 58.1 22.00 REF. 22.89 31.8 12.50 ULTRA SONIC BIN LEVEL SENSOR OPTIONAL [68.6] 27.00 24.00 LOUVER AND PLAN VIEW REF. REMOVABLE FILTER A/C UNITS ONLY 41.9 16.50...
NB0622, NB0922, FB1222, NB1322 Installation and Use Unpacking & Install Prep Remove the carton from the skid. Check for hidden Panel Removal freight damage, notify the carrier immediately if any is found. Retain the carton for the carrier’s inspection. The machine is not bolted to the skid. If strapped remove the strap.
NB0622, NB0922, FB1222, NB1322 Installation and Use Water Supply and Drains The water supply for ice making must be cold, potable water. There is a single ” male flare potable water connection on the back panel. Water Inlet Backflow The design of the float valve and reservoir prevents potable water backflow by means of a 1"...
NB0622, NB0922, FB1222, NB1322 Installation and Use Electrical - All Models The machine does not include a power cord, one Connect electrical power to wires inside the must be field supplied or the machine hard wired to junction box in the back of the cabinet. Use a strain the electrical power supply.
NB0622, NB0922, FB1222, NB1322 Installation and Use Final Check List After connections: Control Operation 1. Wash out the bin. If desired, the interior of the Use and Operation bin could be sanitized. Once started, the ice machine will automatically 2. Locate the ice scoop (if supplied) and have it make ice until the bin or dispenser is full of ice.
NB0622, NB0922, FB1222, NB1322 Installation and Use Initial Start Up and Maintenance 1. Turn the water supply on. Top bearing check: At least twice a year or every time the scale is removed. 2. Switch the electrical power on. Confirm voltage is correct for the model.
Discard or melt all ice made during 6. Remove the water reservoir cover. the previous step. 7. Mix a solution of 8 ounces of Scotsman Clear 13. To sanitize the water system, mix a locally One Scale Remover and 3 quarts of 95-115 approved sanitizing solution.
NB0622, NB0922, FB1222, NB1322 Installation and Use Maintenance: Check Top Bearing This task should only be done by a qualified service technician Breaker Cover The bearing in the breaker should be checked at least two times per year. Check the bearing by: 1.
If the bearing only needs grease, or to confirm the quality of the grease low in the bearing, inject grease into the lower part of the bearing using Scotsman grease needle pn 02-3559-01 and Check Drip Pan For Water Scotsman bearing grease cartridge, pn A36808-001.
NB0622, NB0922, FB1222, NB1322 Installation and Use Maintenance: Sensors The control that senses bin full and empty is a The ice machine senses water by a probe located photo-electric eye, therefore it must be kept clean near the water reservoir. At least twice a year, the so it can “see”.
NB0622, NB0922, FB1222, NB1322 Installation and Use What to do before calling for service Normal Operation: • Controller self test failure. Check the following: The machine will make either flaked or nugget ice, 1. Has the water supply to the ice machine or depending upon the model.
Page 17
NB0622, NB0922, FB1222, NB1322 Information Display Introduction to the Information Display Removal of the front panel provides access to the Power Status Water De-scale Information Display at the bottom of the control. Full Adjust Ice Level This section of the manual provides an explanation...
NB0622, NB0922, FB1222, NB1322 Information Display Use of Information Display and Buttons: Select Scroll Up Escape Button Button Button Scroll Down Display Area Enter Button Button Connection Communication Features: Scroll Up: Changes the display to a menu item higher on the menu list or goes up one number on...
Page 19
NB0622, NB0922, FB1222, NB1322 Information Display Information types include Warnings and Data Data available by scrolling through the menus: • • Warning Bin Level • • Power Interrupts Bin Level Setting • • Time to Clean Freeze Timer (in 00:00 format) •...
NB0622, NB0922, FB1222, NB1322 Information Display % Runtime Calculation Wednesday level 2 Menu Tree Wednesday time 3 Timers Wednesday level 3 Date and Time Preset Compressor Run Time Wednesday time 4 Compressor Run Time Resettable Warnings Wednesday level 4 Power Up Time...
NB0622, NB0922, FB1222, NB1322 Information Display Group Screens Within each group are several screens of either information or settings, like times, that can be changed. Date and Time Groups: No submenus are available. Warnings: Press and release the Enter button to see information on current Warnings Warnings.
NB0622, NB0922, FB1222, NB1322 Information Display Advance Fault Definitions - Flaker or Nugget Self-Test Failure The controller checks for proper operation at power up. If the check shows a problem, this warning or fault will be displayed. No Ice Pending The controller monitors ice making using the photo eyes.
NB0622, NB0922, FB1222, NB1322 Information Display Status List Adv Faults Press and release the down arrow to underline the S in Status. Status Press and release the Enter button to see: Warranty Start: Warranty Start: The display will show the warranty start date after 24 hours of Starts at 24HRS run time.
NB0622, NB0922, FB1222, NB1322 Information Display Cleaning Status: Push and release the Down arrow to put the line under the C in Cleaning. Cleaning Then push and release the Enter button to see. Clean Interval: The Clean Interval. Then press and release the Down arrow to see: 6 Months The Next Clean Due in x HRS.
NB0622, NB0922, FB1222, NB1322 Information Display Revision Timers Push and release the Down arrow to put the line under the R in Revision. Revision Then push and release the Enter button to see: Revision. SW Rev number. Smart-Board SW R...
Page 26
NB0622, NB0922, FB1222, NB1322 Information Display When done, push and release the Enter key. Then press and release the Down arrow to view the Model Number Model number. Then press and release the Down arrow to view the Serial Number...
Page 27
NB0622, NB0922, FB1222, NB1322 Information Display Auger Warning - Press and release the Down arrow to view the Auger warning setpoint Ice Detect Warning - Press and release the Down arrow to view the Ice Detect Any of the above can be modified by changing the settings as noted below.
NB0622, NB0922, FB1222, NB1322 Information Display To Set the 7 Day Programmable Ice Level There are four times and levels available for each day of the week. Setup PGM Bin Level Use Up or Down Arrow keys to scroll to PGM Bin Level screen. When the P in PGM is underlined, press and release the Enter key.
Page 29
NB0622, NB0922, FB1222, NB1322 Information Display This table shows the default times and levels, which can be changed using the instructions on the previous page. Monday Tuesday Wednesday Thursday Friday Saturday Sunday Time 1 12 AM 12 AM 12 AM...
NB0622, NB0922, FB1222, NB1322 Information Display Network Configuration Used only when connected to a network. There is an Ethernet connector on the back of the Information Display board. If desired, route a network cable thru the cabinet and connect your network to it.
Supplied Software Description: Scotsman Prodigy Tech Tool is a software program designed to access the Prodigy ice machine 's Information Display control. It can read and display the data in the controller. The data is converted to chart form and can then be saved and / or printed. It is on the CD-ROM and must be installed onto the PC that will be used to connect through the USB port.
With the unit powered and connected to the computer's USB port, Open Scotsman Prodigy: Start, All Programs, Scotsman Prodigy, Prodigy Click on Get File. The software will automatically begin to download the information. Once that is complete either click on Chart Data or select a new log file to review.
NB0622, NB0922, FB1222, NB1322 Information Display Chart Definitions • Op Mode = The mode the controller was in at the time shown • Error Code = The codes, if any, of any diagnostic codes. • Warning = The codes, if any, of any warnings. Same codes as diagnostic •...
NB0622, NB0922, FB1222, NB1322 Information Display Access through Ethernet 1. After installation, connection to a network, and power up, scroll down to locate IP Address. 2. Enter that IP address into an internet browser like Internet Explorer or Firefox. 3. A Prodigy logo screen will appear. After a few seconds it will update and show a screen similar to the one here.
NB0622, NB0922, FB1222, NB1322 Information Display Appendix NAFEM Protocol. See the NAFEM website, www.nafem.org, for more information. August 2011 Page 20...
Page 37
SCOTSMAN ICE SYSTEMS 775 Corporate Woods Parkway Vernon Hills, IL 60061 800-726-8762 www.scotsman-ice.com 17-3368-01...
Need help?
Do you have a question about the FB1222 and is the answer not in the manual?
Questions and answers