Water - Remote Models - Scotsman F0522 Installation And User Manual

Modular flaked and nugget/ prodigy plus d series
Table of Contents

Advertisement

N0422, F0522, N0622, F0822, N0922, F1222, N1322, F1522
D Series Air, Water or Remote User Manual

Water - Remote Models

The water supply for ice making must be cold, potable
water. There is a single 3 8" male flare potable water
connection on the back panel.
Backflow
The design of the float valve and reservoir prevents
potable water backflow by means of a 1" air gap
between the reservoir's maximum water level and the
float valve water inlet orifice.
Drain
There is one ¾" FPT condensate drain fitting at the
back of the cabinet.
Attach Tubing
1. Connect the potable water supply to the potable
water fitting, 3 / 8" OD copper tubing or the
equivalent is recommended.
2. Change the cartridge on the existing water filter (if
any present).
3. Connect the drain tube to
the condensate drain fitting.
Use rigid tubing.
4. Vent the drain tubing
between the ice machine
and the building drain.
To Remote Condenser
Potable Water
Connection
Drain Vent
Condensate Drain
October 2014
Do not Tee ice machine drains into the drain tube
from the ice storage bin or dispenser. Back ups
could contaminate and / or melt the ice in the bin or
dispenser. Be sure to vent the bin drain.
Follow all local and national codes for tubing, traps
and air gaps.