Scotsman F0522 Installation And User Manual

Modular flaked and nugget/ prodigy plus d series

Advertisement

Installation and User's Manual for
Modular Flaked and Nugget Ice Machines
Prodigy Plus D Series Models
F0522, F0822, F1222, F1522, N0422, N0622,
N0922 and N1322
Air Cooled, Water Cooled and Remote Air Cooled

Advertisement

Table of Contents
loading

Summary of Contents for Scotsman F0522

  • Page 1 Installation and User’s Manual for Modular Flaked and Nugget Ice Machines Prodigy Plus D Series Models F0522, F0822, F1222, F1522, N0422, N0622, N0922 and N1322 Air Cooled, Water Cooled and Remote Air Cooled...
  • Page 2: Table Of Contents

    N0422, F0522, N0622, F0822 Cabinet Layout ........
  • Page 3: Installation

    N0422, F0522, N0622, F0822, N0922, F1222, N1322, F1522 D Series Air, Water or Remote User Manual Installation: This machine is designed to be used indoors, in a The quality of the water supplied to the ice machine controlled environment. Operation outside the limits will have an impact on the time between cleanings listed here will void the warranty.
  • Page 4: Location

    N0422, F0522, N0622, F0822, N0922, F1222, N1322, F1522 D Series Air, Water or Remote User Manual Location: Bin compatibility While the machine will operate satisfactorily within the listed air and water temperature limits, it will produce All models have the same footprint: 22 inches wide more ice when those temperatures are nearer the by 24 inches deep.
  • Page 5: N0422, F0522, N0622, F0822 Cabinet Layout

    N0422, F0522, N0622, F0822, N0922, F1222, N1322, F1522 D Series Air, Water or Remote User Manual N0422, F0522, N0622, F0822 Cabinet Layout October 2014 Page 4...
  • Page 6: N0922, F1222, N1322, F1522 Cabinet Layout

    N0422, F0522, N0622, F0822, N0922, F1222, N1322, F1522 D Series Air, Water or Remote User Manual N0922, F1222, N1322, F1522 Cabinet Layout October 2014 Page 5...
  • Page 7: Unpacking & Install Prep

    N0422, F0522, N0622, F0822, N0922, F1222, N1322, F1522 D Series Air, Water or Remote User Manual Unpacking & Install Prep Remove the carton from the skid. Check for hidden Panel Removal freight damage, notify the carrier immediately if any is found.
  • Page 8: Water - Air Or Water Cooled

    N0422, F0522, N0622, F0822, N0922, F1222, N1322, F1522 D Series Air, Water or Remote User Manual Water - Air or Water Cooled The water supply for ice making must be cold, potable water. There is a single 3 8” male flare potable water Water Inlet connection on the back panel.
  • Page 9: Electrical - All Models

    N0422, F0522, N0622, F0822, N0922, F1222, N1322, F1522 D Series Air, Water or Remote User Manual Electrical - All Models The machine does not include a power cord, one Connect electrical power to wires inside the junction must be field supplied or the machine hard wired to box in the back of the cabinet.
  • Page 10: Refrigeration - Remote Condenser Models

    N0422, F0522, N0622, F0822, N0922, F1222, N1322, F1522 D Series Air, Water or Remote User Manual Refrigeration - Remote Condenser Models Remote condenser models have additional installation needs. The correct remote condenser fan and coil must be connected to the ice making head. Liquid and...
  • Page 11: Remote Condenser Location - Limits

    N0422, F0522, N0622, F0822, N0922, F1222, N1322, F1522 D Series Air, Water or Remote User Manual Remote Condenser Location - Limits Use the following for planning the placement of the Configurations that do NOT meet these requirements condenser relative to the ice machine must receive prior written authorization from Scotsman to maintain warranty.
  • Page 12: For The Installer: Remote Condenser

    N0422, F0522, N0622, F0822, N0922, F1222, N1322, F1522 D Series Air, Water or Remote User Manual For The Installer: Remote Condenser Locate the condenser as near as possible to the interior location of the ice machine. Allow it plenty of space for air and cleaning: keep it a minimum of two feet away from a wall or other rooftop unit.
  • Page 13: Precharged Line Routing - Remote Only

    N0422, F0522, N0622, F0822, N0922, F1222, N1322, F1522 D Series Air, Water or Remote User Manual Precharged Line Routing - Remote Only Do not connect the precharged tubing until all routing 3. Route the refrigerant tubes thru the roof opening.
  • Page 14: Coupling Instructions - Remote Only

    N0422, F0522, N0622, F0822, N0922, F1222, N1322, F1522 D Series Air, Water or Remote User Manual Coupling Instructions - Remote Only The couplings on the ends of the pre-charged line 6. Continue tightening the swivel nut until it bottoms sets are self-sealing when installed properly.
  • Page 15: Water - Remote Models

    N0422, F0522, N0622, F0822, N0922, F1222, N1322, F1522 D Series Air, Water or Remote User Manual Water - Remote Models The water supply for ice making must be cold, potable Do not Tee ice machine drains into the drain tube water.
  • Page 16: Final Check List

    N0422, F0522, N0622, F0822, N0922, F1222, N1322, F1522 D Series Air, Water or Remote User Manual Final Check List After connections: Caution: Do not place anything on top of the ice machine, including the ice scoop. Debris and moisture 1. Wash out the bin. If desired, the interior of the bin from objects on top of the machine can work their way could be sanitized.
  • Page 17: Initial Start Up And Maintenance

    N0422, F0522, N0622, F0822, N0922, F1222, N1322, F1522 D Series Air, Water or Remote User Manual Initial Start Up and Maintenance 1. Turn the water supply on. Remote models also Sanitizing: Every time the scale is removed or as open the liquid line valve.
  • Page 18: Maintenance: Scale Removal And Sanitation

    Drain Water 6. Remove the water reservoir cover. 7. Mix a solution of 8 ounces of Scotsman Clear One Discard or melt all ice made during the previous Scale Remover and 3 quarts of 95-115 degree F. step.
  • Page 19: Maintenance: Check Top Bearing

    N0422, F0522, N0622, F0822, N0922, F1222, N1322, F1522 D Series Air, Water or Remote User Manual Maintenance: Check Top Bearing This task should only be done by a qualified service technician The bearing in the breaker should be checked at least two times per year.
  • Page 20: Bearing Service

    N0422, F0522, N0622, F0822, N0922, F1222, N1322, F1522 D Series Air, Water or Remote User Manual Bearing Service This task should only be done by a qualified service technician If the grease is uniformly white, no further action is needed. If very gray, rusty, wet or has any embedded metal, have the bearing replaced.
  • Page 21: Maintenance: Sensors

    N0422, F0522, N0622, F0822, N0922, F1222, N1322, F1522 D Series Air, Water or Remote User Manual Maintenance: Sensors The control that senses bin full and empty is a photo- The ice machine senses water by a probe located electric eye, therefore it must be kept clean so it near the water reservoir.
  • Page 22: Options

    N0422, F0522, N0622, F0822, N0922, F1222, N1322, F1522 D Series Air, Water or Remote User Manual Options Vari-Smart Use of adjustable ice level control Optional adjustable ice level control (KVS). When There are several positions the ice level can be set to,...
  • Page 23: What To Do Before Calling For Service

    N0422, F0522, N0622, F0822, N0922, F1222, N1322, F1522 D Series Air, Water or Remote User Manual What to do before calling for service Normal Operation: Check the following: 1. Has the water supply to the ice machine or building been shut off? If yes, the ice machine will...
  • Page 24 SCOTSMAN ICE SYSTEMS 775 Corporate Woods Parkway Vernon Hills, IL 60061 800-726-8762 www.scotsman-ice.com 17-3533-01...

This manual is also suitable for:

F1522F1222F0822N0422N0622N0922 ... Show all

Table of Contents