I/O terminal connector - Used in applications for e.g. motion detection, event triggering,
time lapse recording and alarm notifications. In addition to an auxiliary power and a GND
pin, it provides the interface to:
•
1 digital output - For connecting external devices such as relays and LEDs. Con-
nected devices can be activated by the VAPIX® Application Programming Interface,
output buttons on the Live View page or by an Event Type. The output will show as
active (shown under Events > Port Status) if the alarm device is activated.
•
1 digital input - An alarm input for connecting devices that can toggle between an
open and closed circuit, for example: PIRs, door/window contacts, glass break detectors, etc. When a signal is received
the state changes and the input becomes active (shown under Events > Port Status).
Notes:
•
The I/O connector on AXIS P1343-E and AXIS P1344-E is connected to the housing electronics (fan/heater) at delivery,
see illustration on page 7, and will trigger an input port event to indicate a fan or heater error when activated. See
Events, on page 23, for information on how to set up an event.
•
For information on how to connect external devices, refer to the Installation Guide supplied with the product.
Function
Pin
GND
1
3.3V DC Power
2
Digital Input
3
Digital Output
4
The following connection diagram gives an example of how to connect an auxiliary device to AXIS P1343/-E/AXIS P1344/-E.
Notes
Ground
Can be used to power auxiliary equipment.
Note: This pin can only be used as power out.
Connect to GND to activate, or leave floating (unconnected) to
deactivate.
AXIS P1343-E and AXIS P1344-E: Connected to housing electronics
at delivery.
Uses an open-drain NFET transistor with the source connected to
GND. If used with an external relay, a diode must be connected in
parallel with the load, for protection against voltage transients.
3.3V
max. 50mA
D
G
S
AXIS P1343/-E/AXIS P1344/-E - Unit connectors
1
E.g. push button
2
3
4
42
Pin 4
Pin 2
Pin 1
Pin 3
Specifications
Max load = 50mA
Min. input = -40V DC
Max. input= +40V DC
Max. load =100 mA
Max. voltage = + 40V DC