Shower Installation - Mira events XS Installation & User Manual

Surface mounted all-in-one manual power shower
Table of Contents

Advertisement

3. Shower Installation

The following installation procedure is based on a bottom entry pipework configuration
(rising hot and cold water supplies) and a top entry electrical supply configuration (via
miniature trunking from above). Using this procedure as a guide, adjust the steps for
alternative water supply or electrical supply configurations as appropriate.
3.1.
Decide on a suitable location for
the Mira Extreme avoiding buried
cables and pipes. Leave a
minimum distance of 200 mm
from the ceiling to allow for the
fitting and removal of the cover.
Ensure that when the hose
retaining ring is placed on the
lowest position on the slide bar,
there is a minimum distance of
25 mm between the handset
and the bath or shower tray
spillover when the handset is
hanging down.
3.2.
Fit the three rubber feet into the
recesses in the case as shown.
The feet will reduce the noise
transmitted by the power shower
through the wall.
3.3.
Remove the temperature knob
concealing cap.
3.4.
Insert the push-fit tool between
the temperature control knob and
cover
temperature indicator and lever
off the temperature knob .
3.5.
Unscrew the three retaining
screws sufficiently to remove the
shower cover.
Note! The cover retaining screws
are captive and need not be
removed.
directly
under
Spill-over level
Cover Retaining
Screws
the
Cover Retaining
Screw
Hose Retaining
Ring
25 mm Minimum
Rubber
Feet
Push-fit
Release
Tool
Concealing
Temperature
Control Knob
Cap
17