QuickSpecs
Technical Specifications
(not on Superdome with mx2
processor modules)
RS-232C Serial Ports
RS-232C Serial Ports
RS-232C Serial Ports
RS-232C Serial Ports
10/100Base-T Ethernet
10/100Base-T Ethernet
10/100Base-T Ethernet
10/100Base-T Ethernet
DIMM Density
DIMM Density
DIMM Density (MB)
DIMM Density
Site planning and
Site planning and
Site planning and
Site planning and
installation included
installation included
installation included
installation included
Maximum Heat
Maximum Heat
Maximum Heat
Maximum Heat
dissipation (BTUs/hour)
dissipation
dissipation
dissipation
Typical Heat dissipation
Typical Heat dissipation
Typical Heat dissipation
Typical Heat dissipation
(BTUs/hour)
Depth
Depth
Depth
Depth (in/mm)
Width (in/mm)
Width
Width
Width
Height (in/mm)
Height
Height
Height
Weight
Weight
Weight (lbs/kg)
Weight
Electrical Characteristics
Electrical Characteristics
Electrical Characteristics
Electrical Characteristics
AC input power-Option 7: 3
phase 5 wire input
AC input power-Option 6: 3
phase 4 wire input
Current requirements at 220V-
240V
Option 7:
3-phase 5-wire input
Option 6:
3-phase 4-wire input
Required Power Receptacle-
Options 6 and 7
Maximum Input Power (watts)
Typical Input Power (watts)
Environmental Characteristics
Environmental Characteristics
Environmental Characteristics
Environmental Characteristics
Acoustics
Operating temperature
Non-operating temperature
Maximum rate of temperature
change
Operating relative humidity
Operating altitude
Non-operating altitude
Regulatory Compliance
Regulatory Compliance
Regulatory Compliance
Regulatory Compliance
Safety
Key Dates
Key Dates
Key Dates
Key Dates
First CPL date
First ship date
DA - 11717
North America — Version 15 — January 3, 2005
HP Integrity Superdome Servers: 16-socket, 32-
HP Integrity Superdome Servers: 16-socket, 32-
HP Integrity Superdome Servers: 16-socket, 32-
HP Integrity Superdome Servers: 16-socket, 32-
Y
Y (Windows does not support
the 10/100 Base-T Ethernet, A
Gigabit Ethernet card is
required for Windows)
512/1024
Y
28,969
20,131
48.03/1,220
30/762
77.16/1,960
1102.31/500
200 240 VAC phase to neutral, 5 wire, 50/60 Hz
200 240 VAC phase to phase, 4 wire, 50/60 Hz
24 A
44 A
None. Cord, plug and included. Receptacle should be ordered separately. Electrician must
hard wire receptacle to site power.
8,490
5,900
4 cells, 32 GB, 4 I/O chassis
with 6 PCI each
65 dB
68° to 86°F (20°C to 30°C)
-40° to 158°F (-40° to 70°C)
68°F/hr (20°C/hr)
15% to 80% @ 86°F (30°C)
0 to 10,000 ft (0 to 3.1 km)
0 to 15,000 ft (0 to 4.6 km)
IEC 950:1991+A1, +A2, +A3, +A4;
EN60950:1992+A1, +A2, +A3, +A4, +A11;
UL 1950, 3rd edition;
cUL CSA C22.2 No. 950 95
6/03
3Q03
socket, and 64-socket
socket, and 64-socket
socket, and 64-socket
socket, and 64-socket
Y
Y (Windows does not support
the 10/100 Base-T Ethernet, A
Gigabit Ethernet card is
required for Windows)
512/1024
Y
41,614
33,439
48.03/1,220
30/762
77.16/1,960
1318.36/598
24 A
44 A
12,196
9,800
8 cells, 32 GB, 4 I/O chassis
with 6 PCI each
Y
Y (Windows does not
support the 10/100 Base-
T Ethernet, A Gigabit
Ethernet card is required
for Windows)
512/1024
Y
83,288
66,877
48.03/1,220
60/1,524
77.16/1,960
2636.73/1,196
24 A
44 A
24,392
19,600
16 cells, 32 GB, 4 I/O
chassis with 6 PCI each
Page 36