Assemble pressure roller as shown in Parts Drawing,
page 7. Attach pressure roller assembly to inline
valve.

Pressure Relief Procedure

WARNING
To help prevent injection injuries,
follow this procedure whenever
you stop painting.
psi/MPa/bar
1. Put inline valve trigger safety in SAFETY ON
position (Fig. 1).
2. Shut off power to pump.

Installation

D When connecting EvenFlow roller frame to the
Contractort Inline Valve, use a wrench to tighten.
3. Turn prime/spray valve to PRIME position to
relieve pressure in system.
4. Put inline valve trigger safety in SAFETY OFF
position, and trigger inline valve to relieve any
pressure in hose.
5. Put inline valve trigger safety in SAFETY ON
position, and keep pump prime/spray valve in
PRIME position until you paint again.