Accessory Suction Tube Kit

Suction Tube Kit 240465

Ref.
No.
Part No.
Description
201
232692
KIT ASSEMBLY, suction tube
202
193411
NIPPLE
203
193459
TUBE, recirculation
204
103473
TIE, wire
The Suction Kit, listed above, can be installed for
drawing fluid from a container that is not directly under
the unit. Install the Suction Kit as follows (see Fig. 4):
1. Remove the following parts from the stand unit:
recirculation tube (28), suction tube (3), male
connector (44), and suction line strainer (43). See
the Parts Drawing on page 13.
2. Apply thread sealant (specified in Fig. 4) to the
threads of the nipple (202).
3. Thread the nipple (202) into the pump inlet.
4. Thread the fitting of the suction tube assembly
(201) onto the nipple (202).
5. Install the new, longer recirculation tube (203) in
place of the old one.
6. Bundle the new suction tube (201) and
recirculation tube (203) with the wire ties (204).
7. Route the new tubes into the remote fluid
container.
} Apply Graco Thread Sealer, or LoctiteR 567, or equiv-
alent to threads.
Qty.
1
1
1
5
Fig. 4
202}
201
203
308846
204
8172A