Fluid Filter Kit 240440 - Graco Pro/Delta Spray 240367 Instructions-Parts List Manual

Acetal husky 307, stand mount, pro/ delta spray packages 100 psi (0.7 mpa, 7 bar) maximum fluid working pressure 100 psi (0.7 mpa, 7 bar) maximum air inlet pressure
Table of Contents

Advertisement

Fluid Filter Kit 240440

Ref.
No.
Part No.
Description
101
114361
FILTER, fluid
102
113322
CONNECTOR, male
103
054188
TUBE; PTFE;R3/8" O.D.
104
113534
ELBOW, male x female
105
111917
NIPPLE; Nylon
The Fluid Filter Kit, listed above, can be installed to
filter fluid drawn by the suction tube after it comes out
of the pump. Install the Fluid Filter Kit as follows (see
Fig. 3):
1. Apply thread sealant (specified in Fig. 3) to all
male threads in this kit.
2. Remove the male connector (6) and the PTFE R
tube (18) that connect to the top of the tee (5).
See the Parts drawing on page .
3. Thread the nipple (105) into the female threads of
the elbow (104).
4. Thread the nipple (105), with the elbow (104)
attached to it, into the tee (5).
5. Thread the fluid filter (101) onto the male threads
of the elbow (104).
6. Thread the male connector (102) into the fluid filter
(101).
7. Turn the fluid filter/male connector assembly
towards the elbow (27). This makes connecting
the tube (103) in step 8 easier.
8. Cut the PTFERtube (103) to the proper length,
and install it to run from the male connector (102)
to the elbow (27).
14
308846
Accessory Fluid Filter Kit
{ To avoid sharp bends in the tube, you may have to cut
Qty.
it to a shorter length.
1
} Apply Graco Thread Sealer, or LoctiteR 567, or equiv-
1
alent to male threads.
8 in.
Y For initial installation, make sure the dome is firmly
2
hand tightened onto the filter body. Do not use a
1
tool. During subsequent service, hand tighten
more firmly to prevent drips.
Fig. 3
27
103{
103}
102}
101Y
104}
105}
5
8114A

Advertisement

Table of Contents
loading

Table of Contents