3.3 Operation from Local/Remote Terminal

Overview and
The following discussions apply to control by both the Terminal and Modem
syntax
devices. Once a user has fulfilled the password requirement for Modem access,
the communication is identical to Terminal control.
Commands listed in this section detail command syntax and action taken.
Commands consist of a command field and a parameter field. Each command
field and parameter field is space delimited. Optional parameters are indicated
by square brackets, [ ], and conditional parameters are indicated by braces, {}.
For example, COMMAND_NAME parameter1 {parameter2} [parameter3]
indicates that parameter1 must be entered, parameter2 entered only when a
certain condition is met (certain option is installed, etc.), and parameter3 is
optional. Both commands and parameters may be entered in upper or lower
case; the interface is not case-sensitive.
Incorrect or incomplete commands result in "Invalid Command" being displayed
at the terminal. Parameter errors on User commands generate "Invalid parameter
name" where parameter name is the name of the incorrectly entered parameter.
User
NOTE: Any commands controlling carriers, programs, or services may be
commands
disabled from COMPEL .
ABORT
Insert is terminated. See TEMP command.
ABORTREC x
x: C - make the unit's permanent setting equal to the last commanded setting
S - make the unit's permanent setting equal to the last successful setting
Command either 1) aborts an ongoing automated recovery; 2) aborts the suc-
cessful results of an automated recovery; or 3) accepts the successful results of
an automated recovery. With either value for x, this command is interpreted as
a direct local user command to establish/confirm the unit's permanent settings.
ADDE location COMPEL-req [tags-req] [aud1] [aud1_rt] [aud2] [aud2_rt]
[margin]
location: Value from 1 up to max (highest entry #) indicating location in Preset
table.