Graco 231-353 Instructions-Parts List Manual page 16

Electric, 120 vac 390sts airless paint sprayer a series
Table of Contents

Advertisement

TYPE OF PROBLEM
Low output
(continued)
Drain valve leaks
Transducer leaks
No output: motor runs and
pump strokes
No output: motor runs but
pump does not stroke
Intermediate Problem Solving
WHAT TO CHECK
If check is OK, go to next check
3. Release gun trigger. Observe resting position of
pump rod (107).
4. Check electrical supply with volt meter. Meter
should read 105–125VAC.
5. Check extension cord size and length; must be
at least 12 gauge wire and less than 150 ft
(45 m) long.
6. Check motor brushes. See Electrical – What To
Check, item 4, on page 14.
7. Check motor start board (47) by substituting
with a good board.
CAUTION: Do not perform this check until mo-
tor armature is determined to be good. A bad
motor armature can burn out a good board.
8. Check motor armature for shorts by using an
armature tester (growler) or perform motor test.
See page 18.
1. Check drain valve for correct torque and/or
worn parts. Check for debris trapped on seat.
1. Slight leakage from transducer is normal.
1. Check paint supply.
2. Check for clogged intake strainer.
3. Check for loose suction tube or fittings. See
page 34.
4. Check to see if intake valve ball and piston ball
are seating properly. See page 22.
5. Check for leaking around throat packing nut
which may indicate worn or damaged packings.
See page 22.
6. Release gun trigger. Observe resting position of
pump rod (107).
1. Check displacement pump connecting rod pin
(17). See Fig. 18, page 22.
7. Check connecting rod assembly (15) for dam-
age. See page 28.
8. Be sure crank in drive housing rotates; plug in
sprayer and turn on briefly to check. Turn off
and unplug sprayer. See page 28.
WHAT TO DO
When check is not OK, refer to this column
3. If pump consistently comes to rest with
rod (107) fully extended, the piston pack-
ings and/or piston valve may be worn.
Service the pump. See page 22.
4. Reset building circuit breaker; replace
building fuse. Repair electrical outlet or
try another outlet.
5. Replace with a correct, grounded exten-
sion cord.
6. See page 20.
7. Replace board. See page 27.
8. Replace motor. See page 26.
9. Tighten to 185 in–lb (21 N.m). Clean
valve and replace with new gasket (42a)
and sealant (42d). See page 32.
1. Periodically remove residue from its cyl-
inder port. See page 31.
1. Refill and reprime pump.
2. Remove and clean, then reinstall.
3. Tighten; use thread sealant on npt
threads of adapter (38).
4. Remove intake valve and clean. Check
ball and seat for nicks; replace as need-
ed. See page 22. Strain paint before us-
ing to remove particles that could clog
pump.
5. Replace packings. See page 22. Also
check piston valve seat for hardened
paint or nicks and replace if necessary.
Tighten packing nut/wet-cup.
6. If pump consistently comes to rest with
rod (107) fully extended, the piston pack-
ings and/or piston valve may be worn.
Service the pump. See page 22.
1. Replace pin if missing. Be sure retainer
spring (18) is fully in groove all around
connecting rod.
7. Replace connecting rod assembly. See
page 28.
8. Check drive housing assembly for
damage and replace if necessary. See
page 28.

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

308-548390stsA series

Table of Contents