Cleaning the Log Set and Firebox
During the annual inspection and maintenance
appointment, the service person should clean dust,
lint, and any light accumulation from the logs and
the firebox area. An extra-soft brush should be used
on the logs as they are extremely fragile; a vacuum
cleaner may be used on the firebox. If at any time the
logs cannot be removed or installed without forcing,
the cause must be found. The logs must never be
forced. Follow this sequence:
1. Remove the side trim panels according to the
directions on page 13.
. Remove the glass door according to the direc-
tions on page 13.
3. Remove, clean, and re-install the log set, ob-
serving the directions on log handling and placement
found on page 6.
mAINTENANCE

Convection Blower Service Access

The blower is located behind a panel that can be
accessed by first removing the fuel module. See page
. Remove the two fasteners securing the panel
and pull the panel forward. The blower will come
out with the panel. Disconnect the blower electrical
connector to completely remove the blower from the
unit.