THE HARMAN CLARITY GAS INSERT IS
BUILT FOR USE WITH PROPANE.
Natural Gas conversion kit # 1-00-09009, available
only from the Harman Stove Company, is necessary
to complete the fuel conversion. This kit includes,
NG regulator knob assembly, Pilot orifice, three
burner orifices, Instructions, and a conversion label,
which must be affixed to the valve upon completion
NOTE: THE CONVERSION SHALL BE CAR-
RIED OUT IN ACCORDANCE WITH THE RE-
QUIREMENTS OF THE PROVINCIAL OR LOCAL
AUTHORITIES HAVING JURISDICTION AND IN
ACCORDANCE WITH REQUIREMENTS OF THE
CURRENT EDITION OF THE NATIONAL FUEL
GAS CODE, ANSI Z223.1 or the CAN/CGA-B149
INSTALLATION CODES.
CAUTION: LABEL ALL WIRES PRIOR
TO DISCONNECTION WHEN SERVIC-
ING CONTROLS. WIRING ERRORS CAN
CAUSE IMPROPER AND DANGEROUS
OPERATION. VERIFY PROPER OPERA-
TION AFTER SERVICING.
IMPORTANT: Perform a leak test upon com-
pletion of the fuel conversion.
SEE WIRING DIAGRAM ON PAGE 19
NATURAL
PROPANE

Appendix A: Fuel Conversion

Steps for completing the fuel conversion:
Prior to installing the fuel conversion, remove
the Glass door and the log set, to gain access to the
burner module. Remove the burner tubes by sliding
to the left while lifting upward. Remove the burner
cover plate and the tube box top as shown.
Step 1: Remove pilot hood with a 7/16" wrench.
Inside, you will find and discard the Propane ori-
fice. Install the new Natural Gas orifice from the kit.
Tighten the pilot hood and assure proper alignment
of the directional openings.
Step : Using a 1/ in. deep-well socket, remove
the three main burner orifices. Install the new ori-
fices accordingly; Front = #47, Middle = #56, Rear =
#44. Apply a thread sealer such as teflon tape, to the
orifices prior to installing. (See Appendix C)
Step 3: Using a small flat-blade screwdriver, re-
move the three screw that hold the LP knob module
in place. Remove the module and replace it with the
Natural Gas module from the kit. See kit instruc-
tions.
Step 4: Affix the conversion label to the valve so
that any future service tech etc... can plainly see that
the valve was converted.
Step 5: Mark the appropriate fuel box on the unit
label, pictured at left, using a permanent marker.