Harman Stove Company Harman Clarity 828i Installation And Operating Manual

Gas fireplace insert
Hide thumbs Also See for Harman Clarity 828i:

Advertisement

INSTAllATION ANd OPErATINg mANuAl
The harman Clarity 828i gas Fireplace Insert

SAFETY NOTICE

PlEASE rEAd ThIS ENTIrE mANuAl bEFOrE YOu IN-
STAll ANd uSE YOur NEw rOOm hEATEr. FAIlurE
TO FOllOw INSTruCTIONS mAY rESulT IN PrOPErTY
dAmAgE, bOdIlY INjurY, Or EvEN dEATh.
IF ThIS hArmAN STOvE IS NOT PrOPErlY INSTAllEd,
A hOuSE FIrE mAY rESulT. FOr YOur SAFETY, FOllOw
INSTAllATION dIrECTIONS.
CONTACT lOCAl buIldINg Or FIrE OFFICIAlS AbOuT
rESTrICTIONS ANd INSTAllATION INSPECTION
rEQuIrEmENTS IN YOur ArEA.
CONTACT YOur lOCAl AuThOrITY (SuCh AS mu-
NICIPAl buIldINg dEPArTmENT, FIrE dEPArTmENT,
FIrE PrEvENTION burEAu, ETC.) TO dETErmINE ThE
NEEd FOr A PErmIT.
CETTE guIdE d'uTIlISATION EST dISPONIblE EN
FrANCAIS. ChEz vOTrE CONCESSIONNAIrE dE hAr-
mAN STOvE COmPANY.
"Ce manuel est disponible en Français sur demande"
SAvE ThESE INSTruCTIONS.
− FOr YOur SAFETY: whAT TO dO IF
YOu SmEll gAS
• do not try to light any appliance.
• Open windows.
• Extinguish any open flame.
• do not touch any electrical switch;
do not use any phone in your building.
Follow the gas supplier's instructions.
• If you can not reach your gas sup-
plier, call the fire department.
r7

Advertisement

Table of Contents
loading

Summary of Contents for Harman Stove Company Harman Clarity 828i

  • Page 1: Safety Notice

    INSTAllATION ANd OPErATINg mANuAl The harman Clarity 828i gas Fireplace Insert “Ce manuel est disponible en Français sur demande” SAFETY NOTICE − FOr YOur SAFETY: whAT TO dO IF PlEASE rEAd ThIS ENTIrE mANuAl bEFOrE YOu IN- STAll ANd uSE YOur NEw rOOm hEATEr. FAIlurE...
  • Page 2: Table Of Contents

    TAblE OF CONTENTS INTRODUCTION ............3 INSTALLATION ............. 4 Clearances ..............4 Venting ............... 7 Test for Flue Spillage ..........8 ASSEMBLY ..............5 Connecting to a Gas Supply ........8 Connecting the Cordset and Thermostat ....9 Installing into a Fireplace ........10 Air Shutter Adjustment ..........
  • Page 3: Introduction

    INTrOduCTION The Harman Clarity 88I Vented Gas Fireplace When operating your Harman Clarity Fireplace In- Insert is a listed, gas-fired, vented room heater tested sert, respect basic safety standards. by Intertek Testing Services/Warnock Hersey to ANSI Read these instructions carefully before you attempt standard Z1.88-00, CSA.33-M0, and CAN/ to operate the heater.
  • Page 4: Installation

    INSTAllATION IMPORTANT NOTICE 10" 10" Due to high temperatures, the Clarity 88I Vented Gas Fireplace Insert should be located out of traffic and away from furniture and draperies. Children and adults should be alerted to the hazards of high surface temperatures and should stay away to avoid burns or clothing ignition.
  • Page 5: Assembly

    ASSEmblY Removing the Glass door The Clarity 88I Fireplace Insert comes with the NOTE: The glass door is heavy. Be prepared for log set packed inside the firebox. The three trim its weight when lifting it to avoid damage during panels and two wing brackets are packed together in removal.
  • Page 6 ASSEmblY Removing and Replacing logs The log set consists of a back log (1), a center log that has a pilot-viewing port in the left end (), -piece ember strip (3), and a cross log that rests on top (4). Remove the cross log, the center log, and the em- ber strips, in that order.
  • Page 7: Venting

    Installation INSTAllATION PRELIMINARY STEPS TO PREPARE FOR The Clarity Fireplace Insert is equipped with its THE INSTALLATION OF THE CLARITY FIRE- own integral draft hood so no additional draft hood PLACE INSERT is required. The heater should be installed so that the Remove the chimney cap if one exists so that the flue draft hood is in the same atmospheric pressure zone may be cleaned and the venting installed.
  • Page 8: Test For Flue Spillage

    INSTAllATION Connecting the Clarity 828I Fireplace In- Test for Flue Spillage sert to a Gas Supply. A spillage test should always be made at the completion of the installation, and at least annually Burn Only the Fuel for Which the Heater is Equipped.
  • Page 9: Connecting The Cordset And Thermostat

    ASSEmblY Connecting the Cord Set Gas Pressure Requirements Correct gas pressure and the use of a properly The Clarity Fireplace Insert, when installed, must sized gas supply line are essential for the safe and be electrically grounded in accordance with local efficient performance of this appliance.
  • Page 10: Installing Into A Fireplace

    ASSEmblY Installing the Insert Into the fireplace Install the top wing panel last using two 1/4-0 fas- The Clarity Fireplace Insert has an integrated draft teners. The mounting holes are near the inside edge hood. Therefore, a separate draft hood is not re- of the side wing panels.
  • Page 11: Air Shutter Adjustment

    ASSEmblY Air Shutter Adjustment The final step of the installation is to check the flame pattern, which should resemble the pattern il- lustrated in the drawing in the next column. The flames should be relatively well-defined and stable. They should be bright yellow with a blue base where attached to the burner ports, and should not look orange or sooty.
  • Page 12: Operation

    OPErATION How to Light the Fire 1. STOP! Read the safety information on the 15. Set the High-Low Regulator to desired setting: turn fully counterclockwise for High and fully clock- lighting instructions label on the stove. wise for Low. . If using the optional thermostat, set thermostat to the lowest setting.
  • Page 13: Maintenance

    mAINTENANCE Maintenance Cleaning the Glass A qualified service person recommended by your The glass may be cleaned with ordinary household Harman dealer should conduct an annual inspection glass cleaner and a soft cloth or paper towel. and maintenance of your Clarity, its venting, and the Removing the Glass door and Trim Panels installation to keep it running safely and efficiently.
  • Page 14: Convection Blower Service Access

    mAINTENANCE Cleaning the Log Set and Firebox Convection Blower Service Access During the annual inspection and maintenance The blower is located behind a panel that can be appointment, the service person should clean dust, accessed by first removing the fuel module. See page lint, and any light accumulation from the logs and .
  • Page 15: Reference Pictures

    mAINTENANCE...
  • Page 16: Appendix A: Fuel Conversion

    THE HARMAN CLARITY GAS INSERT IS BUILT FOR USE WITH PROPANE. Natural Gas conversion kit # 1-00-09009, available only from the Harman Stove Company, is necessary to complete the fuel conversion. This kit includes, NG regulator knob assembly, Pilot orifice, three...
  • Page 17: Appendix B: Altitude De-Rating

    Appendix b: de-rating for high Altitude For high altitude installations above 1370 meters For U.S. installations, the Clarity Fireplace Insert is approved for elevations up to 000 feet using (4500 feet), consult the local gas distributor or the the factory-installed burner injectors. At elevations authority having jurisdiction for proper rating meth- ods.
  • Page 18: Appendix C: Changing Orifices

    Appendix C: Changing Orifices To change the orifices, such as when derating for 8. Remove the center burner. altitude, follow these steps. 9. Remove the front burner. 1. Remove the side trim panels according to the di- 10. Remove the 1/4-0 fasteners and retainer clip rections on page 13 to gain access to the levers that that secure the rear burner, then remove the rear secure the glass door, then remove the glass door...
  • Page 19: Appendix D: Wiring Diagram

    Appendix d: low voltage wiring diagram 10 Volt Wiring Diagram The Clarity Fireplace Insert, when installed, must be electrically grounded in accordance with local codes or, in the absence of local codes, with the current edition of the National Electrical Code, ANSI/NFPA 70 in the United States or the current Canadian Electrical Code CSA 22.1 in Canada.
  • Page 20 PArTS lIST The following replacement parts for your Harman Clarity Fireplace Insert are available from your Harman dealer. 1. Pilot 3-40-09011 36. Burner Module (NG) 1-10-08700 Pilot 3-40-09010 Burner Module (LP) 1-10-08800 . Thermopile 3-0-0819 37. Gold Bars () 4-40-00141 3.
  • Page 21 EXPlOdEd vIEw Burner Assembly...
  • Page 22 EXPlOdEd vIEw...
  • Page 23: Specifications

    SPECIFICATIONS Tested to ANSI Z1.88-00, CSA .33-M0, CAN/CGA .17-M91. NATURAL GAS PROPANE Input Rating (Btu/hr) (0-1370 m) 37,000 37,000 Min. Input Rating (Btu/hr) (0-1370 m) 5,000 7,500 Injector Sizes (DMS) (front/center/rear (0-1370 m) 47/56/44 57/71/55 Manifold Pressure (in w.c./kPa) 3.5/0.87 10.0/.49 Minimum Manifold Pressure (in w.c./kPa) 1.7/0.4...
  • Page 24: Warranty

    Harman Stove Company. This warranty does not apply if the product has been altered in any way after leaving the factory. Harman Stove Company and its agents assume no liability for “resultant damages of any kind”...

Table of Contents