Test for Flue Spillage

A spillage test should always be made at the
completion of the installation, and at least annually
thereafter.
1. Start all exhaust fans in the home and then close
all doors and windows in the room containing the
heater.
. Light the heater and allow it to run for 5 minutes
on the high output setting. The convection air blower
should be turned off for the test.
3. Remove the left trim panel, which is held in
place by a clip at the bottom and a magnet at the
top, and place a source of smoke (such as a match,
lighter, or a cigarette) in front of the flue spillage test
tube.
The smoke should be drawn into the tube. If it is
not, let the heater run for 5 more minutes and repeat
the test.
4. If the smoke is not drawn into the tube, turn off
the heater and determine why there is no draft. If
necessary, seek expert advice.
For sites with swirling or turbulent wind condi-
tions, a wind cap may solve the problem.
Draft Test Tube
INSTAllATION
Connecting the Clarity 828I Fireplace In-
sert to a Gas Supply.
Burn Only the Fuel for Which the Heater is Equipped.
natural gas or propane, but requires a conversion if
Natural Gas is to be burned. The label on the burner
system module indicates the fuel for which it is
equipped. The Prpoer box must be marked upon
installation or conversion.
Making The Connection
Insert. The inlet fitting is a 1/2" male pipe thread.
tapping should be installed immediately upstream of the
connection to the appliance.
the gas supply piping during any pressure testing of that
system at pressures in excess of 1/ psig (3.5 kPa).
tion during any pressure testing of the gas supply system
at pressures equal to or less than 1/ psig (3.5 kPa).
Remove Left
Wing Cover to
Expose Draft
Test Tube.
The Clarity Fireplace Insert will burn either
NATURAL
PROPANE
The gas inlet is located at the bottom right rear of the
A separate gas shut-off valve and a 1/8" N.P.T. plugged
The Clarity Fireplace Insert must be disconnected from
The Clarity gas control valve must be in the OFF posi-
WARNING: To avoid pipe compounds from
entering into the gas train, apply compounds
only to the male pipe threads and not to the
first two threads.
CAUTION: TEST ALL PIPE JOINTS FOR
LEAKS BEFORE OPERATING