For U.S. installations, the Clarity Fireplace Insert
is approved for elevations up to 000 feet using
the factory-installed burner injectors. At elevations
above 000 feet, U.S. codes require a decrease in
the input rating by changing the burner injectors to a
smaller size. The chart below lists by part numbers
the appropriate injectors for both LP and natural gas
at various altitudes.
For Canadian installations, the Clarity Fireplace
Insert is approved for elevations up to 1370 meters
(4500 feet).
NATURAL GAS
Front
Altitude
Injector Part No.
0-000'
47
000-3000'
47
3000-4000'
48
4000-5000'
49
5000-6000'
49
6000-7000'
50
7000-8000'
50
8000-9000'
51
PROPANE
Front
Altitude
Injector Part No.
0-000'
57
000-3000'
59
3000-4000'
57
4000-5000'
58
5000-6000'
59
6000-7000'
59
7000-8000'
60
8000-9000'
61
THE CONVERSION SHALL BE CAR-
RIED OUT BY A MANUFACTURER'S
AUTHORIZED REPRESENTATIVE IN
ACCORDANCE WITH THE REQUIRE-
MENTS OF THE MANUFACTURER,
PROVINCIAL OR TERRITORIAL
AUTHORITIES HAVING JURISDIC-
TION AND IN ACCORDANCE WITH
THE CURRENT EDITION OF THE
REQUIREMENTS OF THE CAN/CGA-
B141.1 OR CAN/CGA-B141.2 INSTAL-
LATION CODES
Appendix b: de-rating for high Altitude
Harman
Center Harman
Injector Part No.
3-40-64347
56
3-40-64347
56
MALE
56
MALE
56
MALE
57
MALE
57
MALE
58
MALE
58
Harman
Center Harman
Injector Part No.
3-40-5857
71
MALE
71
3-40-5857
71
MALE
71
MALE
71
MALE
71
MALE
71
MALE
71
For high altitude installations above 1370 meters
(4500 feet), consult the local gas distributor or the
authority having jurisdiction for proper rating meth-
ods.
NOTE: The difference in altitude derating require-
ments for the U.S. and Canada is simply a result
of differences in testing standards between the two
countries.
If the installer must convert the unit to adjust for
varying altitudes, an information sticker like the one
below must be filled out and affixed to the appliance
at the time of conversion.
Rear
Injector Part No.
3-40-57356
44
3-40-57356
45
3-40-57356
45
3-40-57356
46
3-40-5857
47
3-40-5857
47
MALE
48
MALE
48
Rear
Injector Part No.
3-40-5771
55
3-40-5771
55
3-40-5771
56
3-40-5771
56
3-40-5771
56
3-40-5771
57
3-40-5771
57
3-40-5771
58
This appliance has been converted for use at an altitude of __________ft.
Orifice Sizes: Front ________
Input (Btu/hr)
_________________
Manifold Pressure
__________________
Fuel Type
_______________________
Converted By _________________________________
Date of Conversion _______________________________
*
When ordering injectors with no item number,
specify MALE or FEMALE and the 2-digit size
number.
Harman
Nominal Btu
Input Rate
3-40-5844
40,000
MALE
38,400
MALE
36,900
MALE
35,400
3-40-64347
34,000
3-40-64347
3,600
MALE
31,300
MALE
30,100
Harman
Nominal Btu
Input Rate
3-40-5855
40,000
3-40-5855
36,900
3-40-57356
36,900
3-40-57356
35,400
3-40-57356
3,600
3-40-5857
3,600
3-40-5857
30,100
MALE
30,100
Center_________
Rear ________
17

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents