Power Supply

The SuperServer 6015TC-LFT has a single 780 watt power supply. This power
supply has the capability of operating at 100 - 240 input volts. Depress both main
power buttons on the front of the chassis and then unplug the AC power cord to
completely remove power from the system before removing the power supply.

Power Supply Failure

If the power supply unit fails, the system will shut down and you will need to replace
the power supply unit. Replacement units can be ordered directly from Supermicro
(PWS-781-1S - see contact information in Chapter 1).

Replacing the Power Supply

Accessing the Inside of the System
1.
Grasp the two handles on either side and pull the unit straight out until it
locks (you will hear a "click").
2.
The top cover of the chassis is secured with four screws: two at the top rear
of the cover and one on each side lip, also near the back. Remove all four,
then place both thumbs in the indentations and push the cover back until it
slides off.
3.
Lift the top cover from the chassis to gain full access to the inside of the
server.
Removing the Power Supply
1.
First, shut down the system and unplug the power cord.
2.
To remove the failed power unit, remove the two screws on the back of the
power supply, which secure it to the chassis.
3.
Lift the unit straight out of the chassis. (See Figure 6-5.)
Installing a New Power Supply
1.
Replace the failed unit with the exact same power supply model from
Supermicro.
2.
Carefully insert the new unit into position in the chassis and secure it with the
two screws at the rear of the unit.