Prepare the Site

Before you install the switch, ensure that the operating environment meets the site requirements
in the following table.
Table 4-3. Site Requirements
Characteristics
Requirements
Mounting
Access
Locate the switch in a position that allows you to access the front panel RJ-45 ports, view the
front panel LEDs, and access the power connector.
Power source
Provide a power connection cord. For information about power specifications for the switch, see
Appendix A,
can accidentally turn off power to the outlet and the switch.
Environmental

Install the Switch

The smart switch can be used on a flat surface or mounted in a standard network equipment
rack.

Install the Switch on a Flat Surface

The switch ships with four self-adhesive rubber footpads. Stick one rubber footpad on each
of the four concave spaces on the bottom of the switch. The rubber footpads cushion the
switch against shock and vibrations.

Install the Switch in a Rack

You need the rack-mount kit supplied with the switch to install the switch in a rack.
To install the switch in a rack:
1.
Attach the supplied mounting brackets to the side of the switch.
GS516TP Gigabit Smart Switch
Desktop installations. Provide a flat table or shelf surface.
Rack-mount installations. Use an EIA standard equipment rack that is grounded and
physically secure. The rack-mount kit supplied with the switch is also required.
Troubleshooting. Ensure that the AC outlet is not controlled by a wall switch, which
Temperature. Install the switch in a dry area, with ambient temperature between 0ºC and
40ºC (32ºF and 104ºF). Keep the switch away from heat sources such as direct sunlight,
warm-air exhausts, hot-air vents, and heaters.
Operating humidity. The installation location should have a maximum relative humidity of
90%, non condensing.
Ventilation. Do not restrict airflow by covering or obstructing air inlets on the sides of the
switch. Keep at least 2 inches (5.08 centimeters) free on all sides for cooling. Be sure that
there is adequate airflow in the room or wiring closet where the switch is installed.
Operating conditions. Keep the switch at least 6 feet (1.83 meters) away from nearest
source of electromagnetic noise, such as a photocopy machine.
Installation
19