● Note
In Bulk function, you may want to set "Continuous" to "AcquisitionMode" register.
You can set "MultiFrame", but acquisition frame number is limited by "AcquisitionFrameCount.
AcquisitionMode = MultiFrame
AcquisitionFrameCount = 2
TriggerMode = On
TriggerSequence = 6
TriggerAdditionalParameter = 3
Start
Acquisition
Command
The trigger can be input in arbitrary timing.
Trigger
VD
Exposure
Frame 1
*Exposure overlaps sensor readout.
*Exposure time is determined by ExposureTime setting.
USB Bus
Copyright © 2013 TOSHIBA TELI CORPORATION, All rights reserved.
AcquisitionFrameRate
Frame 2
TriggerAdditionalParameter
Frame 1
Frame 2
AcquisitionFrameCount
Frame 3
This exposure is
discarded.
Stream
stops
63 / 65
Stop
Start
Counter is reset.
Frame 1
www.toshiba-teli.co.jp
Frame 1