Setting Heater Control; Adjusting For Spraying - Graco VISCON HP 309524L Instructions Manual

High pressure fluid heater 250 psi (50 mpa, 500 bar) maximum working pressure
Table of Contents

Advertisement

Setting Heater Control

(Refer to F
. 11)
IG
1. Set the heater control knob (33) to a trial setpoint of
4 or 5.
2. Start the pump and circulate fluid through the sys-
tem at very low pressure, about 10-12 oz/min
(0.30-0.35 liter/min).
3. After 10 minutes, read the temperature on the ther-
mometer (2). If it does not match the desired tem-
perature, adjust the setpoint.
F
. 11: Setting Heater Control
IG
309524L

Adjusting for Spraying

CAUTION
Operating the heater at its highest setting, over 180°F
(82°C), for long periods of time decreases the heater
life and can cause fluid to dry out; which can clog the
heater and result in a poor finish.
1. Adjust pump pressure and heater setpoint to the
lowest settings needed for good fluid atomization.
2. Set all system back pressure valves (S - F
maintain even fluid pressure at all gun stations.
33
2
05549-524
Operation
. 1) to
IG
15