Operation; Pressure Relief Procedure; Initial Flushing; Priming System - Graco VISCON HP 309524L Instructions Manual

High pressure fluid heater 250 psi (50 mpa, 500 bar) maximum working pressure
Table of Contents

Advertisement

Operation

Operation

Pressure Relief Procedure

WARNING
Read warnings, page 4.
Follow Pressure Relief Procedure when you stop
spraying, and before cleaning, checking, or servicing
equipment.
1. Engage the gun safety lock.
2. Shut off main power to the heater.
3. Circulate fluid for at least 10 minutes to cool the
heated fluid and heater.
4. Shut off all air and fluid supplies.
5. Disengage the safety lock.
6. Hold a metal part of the gun firmly to a grounded
metal pail, and trigger the gun to relieve pressure.
7. Engage the safety lock.
8. Have a container ready to catch the fluid, then open
the fluid drain valve.
14

Initial Flushing

WARNING
Read warnings, page 4.
The heater was tested with lightweight oil, which needs
to be flushed out before using the equipment. Ensure
main power is off and heater is cool before flushing. Use
a compatible solvent, and follow flushing instructions in
your fluid supply and spray gun manual. Do not turn on
heater until fluid lines are clear of solvent.

Priming System

(Refer to F
. 1, page 6)
IG
1. Do not turn on the heater yet.
2. If using an airless spray gun, do not install a spray
tip yet.
3. Start the pump according to the instructions sup-
plied with it.
4. Turn the system director valve (U) to circulate, and
circulate fluid for several minutes.
5. Open the spray gun (Q) at the last outlet to prime
the line. Repeat for all gun stations.
6. Engage the gun safety latch.
7. Shut off the air supply to the pump.
8. Follow Pressure Relief Procedure.
9. Install the gun spray tip.
309524L