Electrical Connections

The instructions given below are designed
specifically for a qualified installer and
should aid him or her to perform all
installation, adjustment and maintenance
operations with absolute precision and in
compliance with all current legislation and
regulations. We strongly recommend that all
operations for the installation of your cooker
be carried out by qualified personnel in
accordance with existing rules and
regulations.
The appliance is predisposed to function with a 240 V
monophase voltage tension. Connection must be carried
out in conformity with the regulations and dispositions of
the laws in force.
Before connecting ensure that:
-
The limiter valve and the electrical mains can support
the voltage of the appliance (see registration plate).
-
The power supply is correctly earthed according to
the regulations in force.
-
The plug or omnipolar interrupter used can be easily
reached once the appliance has been installed.
The appliance is supplied with a 15A supply cord
incorporating a plug. Connect the plug to an appropriate
security socket.
Any modifications to the domestic electrical supply (e.g.
installing a 15A power socket) must be carried out by a
qualified electrician.
If a direct connection to the mains is required, an
omnipolar interrupter with a minimum opening of 3mm
between contacts, dimensioned to the voltage and
corresponding to the regulations in force, should be
interposed between the appliance and the supply. The
yellow/green earth cable must not be interrupted by the
interrupter. The brown coloured phase cable (situated at
terminal "L" of the terminal box) must always be connected
to the network phase. The voltage cable must always be
positioned in such a manner that it at no point reaches a
temperature of 50°C above room temperature. An example
of the best routing is shown in the picture.
In case of substitution of the voltage cable use cable
type H05 RRF having a section suited to the charge, it is
furthermore necessary that the yellow/green earth wire
be approximately 2cm longer than the phase and neutral
wires (see picture).
After connection try out the heating elements allowing
them to function for approximately 3 minutes.
The manufacturer declines all responsibility in case
the prevention of accidents regulations are not
respected.
36
Neutral wire
Phase
Ground (yellow - green)
YES
Gas
pipeline
Electric
wire
Gas
pipeline
Electric
wire
NO