Electrical Connections

The appliance is predisposed to function with a 240V
monophase voltage tension. Connection must be carried
out in conformity with the regulations and dispositions of
the laws in force.
Before connecting ensure that:
-
The limiter valve and the electrical mains can support
the voltage of the appliance (see registration plate).
-
The power supply is correctly earthed according to
the regulations in force.
-
The plug or omnipolar interrupter used can be easily
reached once the appliance has been installed.
The appliance is supplied with a supply cord incorporating
a plug. Connect the plug to an appropriate security
socket.
If a direct connection to the mains is required, an
omnipolar interrupter with a minimum opening of 3mm
between contacts, dimensioned to the voltage and
corresponding to the regulations in force, should be
interposed between the appliance and the supply. The
yellow/green earth cable must not be interrupted by the
interrupter. The brown coloured phase cable (situated at
terminal "L" of the terminal box) must always be connected
to the network phase. The voltage cable must always be
positioned in such a manner that it at no point reaches a
temperature of 50°C above room temperature. An example
of the best routing is shown in the picture.
In case of substitution of the voltage cable use cable
type H05 RRF having a section suited to the charge, it is
furthermore necessary that the yellow/green earth wire
be approximately 2cm longer than the phase and neutral
wires (see picture).
After connection try out the heating elements allowing
them to function for approximately 3 minutes.
The manufacturer declines all responsibility in case
the prevention of accidents regulations are not
respected.
30
YES
Gas
pipeline
Electric
wire
Gas
pipeline
Electric
wire
NO