Table Of Contents; General Information; Packaging List; Appliance Specifications - Lennox Hearth Products Signature X-FIRES-1000-NG Installation And Operation Manual

Catalytic vent-free wall-mounted gas fireplace
Hide thumbs Also See for Signature X-FIRES-1000-NG:
Table of Contents

Advertisement

CONGRATULATIONS!
When you purchased your new gas fireplace, you joined the
ranks of thousands of individuals whose answer to their home
heating needs reflects their concern for aesthetics, efficiency
and our environment. We extend our continued support to help
you achieve the maximum benefit and enjoyment available from
your new gas fireplace.
Thank you for selecting a Lennox Hearth Products gas fireplace
as the answer to your home heating needs.

TABLE OF CONTENTS

Section Contents
1.0
Safety And Warning Information . . . . . . . . . . . . . 2
2.0
General Information . . . . . . . . . . . . . . . . . . . . . . . 3
3.0
Packaging List . . . . . . . . . . . . . . . . . . . . . . . . . . . 3
4.0
Appliance Specifications . . . . . . . . . . . . . . . . . . . 3
5.0
Unpacking the Appliance . . . . . . . . . . . . . . . . . . . 4
6.0
Burn-in Period . . . . . . . . . . . . . . . . . . . . . . . . . . . 4
7.0
8.0
Combustion And Ventilation Air. . . . . . . . . . . . . . 5
9.0
Site Requirements . . . . . . . . . . . . . . . . . . . . . . . . 6
10.0
Gas Supply Routes . . . . . . . . . . . . . . . . . . . . . . . 6
11.0
Preparing The Appliance . . . . . . . . . . . . . . . . . . . 7
12.0
Mounting The Appliance . . . . . . . . . . . . . . . . . . . 8
13.0
Fitting the Surround Assembly . . . . . . . . . . . . . . 9
14.0
Checking The Burner . . . . . . . . . . . . . . . . . . . . . . 10
15.0
Connecting A Gas Line . . . . . . . . . . . . . . . . . . . . 10
16.0
Checking The Gas Connections . . . . . . . . . . . . . . 10
17.0
Gas Pressure Check . . . . . . . . . . . . . . . . . . . . . . . 10
18.0
Spark Gap . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 11
19.0
Briefing The Customer. . . . . . . . . . . . . . . . . . . . . 11
20.0
Servicing . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 12
21.0
Catalysts . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 13
22.0
Testing For Firebox Leakage . . . . . . . . . . . . . . . . 13
23.0
24.0
Troubleshooting Guide. . . . . . . . . . . . . . . . . . . . . 15
25.0
Replacement Parts List . . . . . . . . . . . . . . . . . . . . 16
26.0
27.0
28.0
Product Reference Information . . . . . . . . . . . . . . 20

.0 GENERAL INFORMATION

This appliance is a high efficiency, unvented, flame effect gas heater.
It provides radiant and convected warmth both efficiently and safely
utilizing the latest type catalytic convertor burner technology. The
appliance does not require a flue system of any type as the catalytic
converter cleans the flue products to provide a complete combustion
system, which is intrinsically safe.
These heaters are fitted with a specially designed pilot utilizing an
oxygen depletion sensor (ODS) which responds to the amount of
oxygen available in the room and shuts the heater off before the
oxygen level drops below 18%. It must not be adjusted or put out
of operation. If replaced then manufacturers original parts must be
used. The pilot can be relit only when fresh air is available. Refer to
the Combustion and Ventilation Air section.
The appliance is designed to fit various types of situations as listed
in the Installation Requirements.
This appliance is factory set for operation on the gas type, and at the
pressure stated on the appliance rating plate.
Read all these instructions before commencing installation. All instruc-
tions must be left in the possession of the user for safekeeping.
Page No.

3.0 PACKAGING LIST

Quantity
Description
1
Firebox, burner assembly and wall mounting plate
1
Installation and Operation Manual
1
Warranty Certificate
1
Screw and wall plug pack
1
Rubber grommet
(required - sold separately. see Page 18 for ordering information)
1
Surround Assembly
1
Installation Instruction Sheet

4.0 APPLIANCE SPECIFICATIONS

Gas Type
Gas inlet pressure
Regulator Pressure Setting
Max Energy Input
Min Energy Input
Pilot Energy Input
Burner Pressure
(manifold)
Main burner flow restrictor
(burner orifice)
Oxypilot
Gas Inlet Connection
Ignition
Spark Gap
Please see Data Plate affixed to appliance for current data. This appliance is for use
only with the gas type, and at the pressure stated on the appliance Data Plate.
Table 1
Fireplace
Surround Assembly
X-Fires 1000
Natural Gas
10.5" w.c.
Max.
6" w.c.
Min.
5" w.c.
8,870 BTU/hour
5,110 BTU/hour
560 BTU/hour
3.5" w.c.
High
1.1" w.c.
Low
1.45mm (0.057")
SIT/Bray 908
3/8" NPT at regulator
Piezo spark
1/8" - 3/16"
Propane Gas (LP)
13" w.c.
11" w.c.
10" w.c.
7,500 BTU/hour
5,110 BTU/hour
560 BTU/hour
5.6" w.c.
.9" w.c.
1.03mm (0.04")
SIT/Bray 984
3/8" NPT at regulator
Piezo spark
1/8" - 3/16"
3

Advertisement

Table of Contents
loading

This manual is also suitable for:

Signature x-fires-1000-lp

Table of Contents