Lennox Hearth Products SCANDIUM-NG Installation And Operation Instructions Manual
Lennox Hearth Products SCANDIUM-NG Installation And Operation Instructions Manual

Lennox Hearth Products SCANDIUM-NG Installation And Operation Instructions Manual

Catalytic vent-free fireplaces signature collection

Advertisement

WHAT'S INSIDE
Table of Contents . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2
Safety and Your Fireplace . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2
FREE Safety Guard Offer
(Protects Against Burns)
Important Safety Information . . . . . . . . . . . . . . . . . . . . . . . . . . 4
L'information de sûreté importante
[EN FRANÇAIS]
Información importante de seguridad
[EN ESPAÑOL]
Manufacturer: Focal Point Fires plc. United Kingdom
This is an unvented gas-fired heater. It uses air
(oxygen) from the room in which it is installed.
Provisions for adequate combustion and ventila-
tion air must be provided. Refer to Combustion
and Ventilation Air section in this manual.
This appliance may be installed in an aftermarket permanently located, manufactured (mobile) home, where not
prohibited by local codes. This appliance is only for use with the type of gas indicated on the rating plate. This appli-
ance is not convertible for use with other gases.
WARNING
• HOT GLASS WILL
CAUSE BURNS.
• DO NOT TOUCH GLASS
UNTIL COOLED.
• NEVER ALLOW CHILDREN
TO TOUCH GLASS.
WARNING: If the information in these instructions is
not followed exactly, a fire or explosion may result
causing property damage, personal injury or death.
- Do not store or use gasoline or other flammable
vapors and liquids in the vicinity of this or any other
appliance.
- WHAT TO DO IF YOU SMELL GAS
• Do not try to light any appliance.
• Do not touch any electrical switch; do not use any
phone in your building.
• Immediately call your gas supplier from a neigh-
bor's phone. Follow the gas supplier's instruc-
tions.
• If you cannot reach your gas supplier, call the fire
department.
- Installation and service must be performed by a
qualified installer, service agency or the gas supplier.
P/N 850055M Rev. H 04/2012
. . . . . . . . . . . . . 2
. . . . . . . . . . . . 3–4
. . . . . . . . . . . . 3–4
AVERTISSEMENT
/
• UNE SURFACE VITRÉE CHAUDE PEUT
CAUSER DES BRÛLURES.
• LAISSER REFROIDIR LA SURFACE
VITRÉE AVANT D'Y TOUCHER.
• NE PERMETTEZ JAMAIS À UN ENFANT
DE TOUCHER LA SURFACE VITRÉE.
INSTALLATION AND OPERATION INSTRUCTIONS
Catalytic Vent-Free Fireplaces
Scandium™ Models
MODELS
Scandium-NG and Scandium-LP
Report No. 317-S-05-5 (NG) & 317-S-05b-5 (LP)
INSTALLER: Leave this manual
with the appliance.
Wait...
DON'T
THROW
IT AWAY!
This manual contains
important operating
and safety
information.
CONSOMMATEUR : Conservez cette
notice pour consultation ultérieure.
AVERTISSEMENT: Assurez-vous de bien suivre les instruc-
tions données dans cette notice pour réduire au minimum
le risque d'incindie ou d'explosion ou pour éviter tout
dommage matériel, toute blessure ou la mort.
- Ne pas entreposer ni utilizer d'essence ni d'autres vapeurs
ou liquides inflammables dans le voisinage de cet appareil
ou de tout autre appareil.
- QUE FAIRE SI VOUS SENTEZ UNE ODEUR DE GAZ:
• Ne pas tenter d'allumer d'appareil.
• Ne touchez à aucan interrupteur. Ne pas vous servir des
téléphones se trouvant dans le bâtiment où vous trouvez.
• Appelez immédiatement votre fournisseur de gaz depuis
un voisin. Suivez les instructions du fournisseur.
• Si vous ne pouvez rejoindre le fournisseur de gaz, appelez
le service des incindies.
- L'installation et l'entretien doivent être assurés par un
installateur ou un service d'entretien qualifié ou par le
fournisseur de gaz.
Portland
US
CONSUMER: Retain this manual
for future reference.
INSTALLATEUR : Laissez cette
notice avec l'appareil.
AVISO
/
• EL VIDRIO CALIENTE
CAUSARÁ QUEMADURAS.
• USTED DEBE NUNCA
TOCAR EL VIDRIO CALIENTE.
• LOS NIÑOS DEBEN NUNCA
TOCAR EL VIDRIO.

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the SCANDIUM-NG and is the answer not in the manual?

Questions and answers

Summary of Contents for Lennox Hearth Products SCANDIUM-NG

  • Page 1 WHAT'S INSIDE Scandium-NG and Scandium-LP Table of Contents . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2 Safety and Your Fireplace .
  • Page 2: Table Of Contents

    Thank you for your purchase . We appreciate your business! Safety and Please carefully read and follow all instructions in this manual . Your Fireplace Pay special attention to all warnings and safety information. Following these safety, care, and operation instructions will help ensure many years of dependable and enjoyable service from All parts of your Lennox your fireplace .
  • Page 3 Toutes les parties de votre foyer ¡Todas las partes de la chimenea Lennox Hearth Products deviennent Lennox Hearth Products se ponen EXTRÊMEMENT CHAUDES ! MUY CALIENTES!  Afin d'éviter de vous brûler gravement ou de  Instale una malla o barrera física para evitar vous blesser, installez une grille ou une barrière...
  • Page 4: Important Safety Information

    Important Safety Information L'information de sûreté importante 1. AVERTISSEMENT. Ne pas utiliser l’appareil si le panneau frontal 1. WARNING: Do not operate appliance with the glass front en verre n’est pas en place, est craqué ou brisé. removed, cracked or broken. 2.
  • Page 5: Appliance Installation, Service, And

    Appliance Installation, Appliance Operation Notices General Information Service, and Maintenance Do not operate appliance with the glass Do not build a wood fire. Do not Notices front removed, cracked, or broken. burn wood or other material in these appliances. These fireplaces are unvented gas WARNING: Improper installation, appliances.
  • Page 6: General Information

    General Information The appliance is designed to fit various types of situations as listed in the installation requirements . WARNING This appliance is factory set for operation on the gas type, and This appliance is equipped for (natural or propane) at the pressure stated on the appliance rating plate .
  • Page 7: Packaging List

    Please see Data Plate affixed to appliance for current data. This appliance is for use This Lennox Hearth Products Unvented Gas Room Heater is certified by only with the gas type, and at the pressure stated on the appliance Data Plate.
  • Page 8: Combustion And Ventilation Air

    Example: COMBUSTION AND VENTILATION AIR Vent-free heater #1 9,000 BTU/Hr Vent-free heater #2 23,000 BTU/Hr Gas appliance #1 35,000 BTU/Hr This heater shall not be installed in a confined space or unusually tight (water heater) construction unless provisions are provided for adequate combustion and Total = 67,000 BTU/Hr ventilation air .
  • Page 9: Site Requirements

    The minimum clearance to the ceiling above the appliance is 32” mea- SITE REQUIREMENTS sured from the top of the appliance glass panel . Combustible materials should not be positioned directly in front of the This appliance is designed to be wall-hung . Do not recess any part of appliance within a distance of 40”...
  • Page 10: Mounting The Appliance

    Non-concealed gas connections may be made using the entry points WARNING on the base of the firebox . A concealed gas connection may be made using the knockout hole in the center back of the firebox . Select the most The wall where the appliance is to be installed must appropriate entry point and knock out the relevant hole .
  • Page 11: Checking The Burner

    MOUNTING THE APPLIANCE - continued IMPORTANT Hold heater regulator with a wrench to prevent Insert the wall mounting screws into the top wall plugs, taking care movement when connecting to inlet piping. to leave the screws protruding approximately 3/8” from the wall . Now hang the appliance onto these screws through the two keyhole shaped holes in the back panel of the appliance .
  • Page 12: Checking The Gas Connections

    The test point is situated before the appliance gas valve so it will be CHECKING THE GAS CONNECTIONS necessary to turn off the gas supply before removing the test point screw (figure 6) . Connect the pressure gauge . WARNING Never use an open flame to check for leaks.
  • Page 13: Spark Gap

    SPARK GAP Grill fixing holes Side Piece The gap between the spark electrode and the pilot should be 1/8” to 3/16” to produce a good spark . There should be no need to adjust this (DO NOT ATTEMPT TO ADJUST THE GAP) . If under any circumstances the piezo electric spark fails, the pilot cannot be lit manually .
  • Page 14: Fitting The Glass Facia

    FITTING THE SIDE PANELS Remove the two side panel assemblies from the protective packaging and fit onto the sides of the firebox as shown . Insert the M6 retain- ing screws in the sides of the firebox and ensure they are unscrewed approximately 1/8”...
  • Page 15: Briefing The Customer

    BRIEFING THE CUSTOMER WARNING Do not add logs or ornaments such as pine cones, vermiculite or rock wool. Using these added items can cause sooting. All instructions must be left in the possession of the user for safekeep- ing . If at all possible, show the customer how to light and control the appliance and how to remove and replace the glass facia .
  • Page 16: Servicing

    First, remove the front Glass facia as described in the Fitting the Glass SERVICING Facia section, only in reverse, remove the valve cover (4 screws) and disconnect the gas connection inside appliance . The gas connections WARNING to the gas valve can now be released . Undo the four screws retaining the burner brackets to the base and rear of the firebox .
  • Page 17: Pilot Assembly

    Clean the pilot assembly with a soft brush and blow through . Check the Turn on the fireplace as per the operating instructions, and run at aeration holes are free of any dirt or lint . Clean thoroughly internally, maximum setting for 15 minutes . Position gas sample probe directly the connection can be removed from the base of the pilot assembly over a cata lyst via the outlet grill, on top of the appliance .
  • Page 18: Lighting Instructions And

    LIGHTING INSTRUCTIONS & TURNING OFF APPLIANCE FOR YOUR SAFETY READ BEFORE LIGHTING WARNING: IF YOU DO NOT FOLLOW THESE INSTRUCTIONS EXACTLY, A FIRE OR EXPLOSION MAY RESULT CAUSING PROPERTY DAMAGE, PERSONAL INJURY OR LOSS OF LIFE. • Immediately call your gas supplier from a neighbor’s phone. This appliance has a pilot which must be lit with a piezo spark Follow the gas supplier’s instructions.
  • Page 19: Troubleshooting Guide

    TROUBLESHOOTING GUIDE PROBLEM CORRECTIVE ACTION Igniter sparks but pilot does not light • No gas to Pilot, check the gas line connections . • Air not fully purged . Purge supply or wait longer . • Spark grounding to metal work, reset gap correctly . •...
  • Page 20: Replacement Parts List

    REPLACEMENT PARTS - SCANDIUM™ FocalPointFires Single 24/04/08 DO 005855/0 Lennox L40 Scandium fitting template Artwork Size: W1055 x H530 Replacement Parts POSITION SPIRIT LEVEL ALONG THIS EDGE TO LEVEL TEMPLATE BEFORE MARKING OUT WALL COLOQUE EL NIVEL SOBRE ESTE BORDE PARA NIVELAR LA PLANTILLA ANTES DE MARCAR LA PARED 16”...
  • Page 21: Positioning Of Field

    POSITIONING OF FIELD REMOVABLE PARTS WARNING Glass Door Removal: Remove the four (4) screws indicated, Failure to position the parts in then lift door off. accordance with these diagrams or failure to use only parts specifi- cally approved with this heater may result in property damage or personal injury.
  • Page 22: Specifications

    SPECIFICATIONS -SCANDIUM™ Product Reference Information Cat. No. Model Ship. Wt. Ship. Volume H6065 Scandium-NG 80.7 lb. 12.9 cu. ft. H6071 Scandium-LP 80.7 lb. 12.9 cu. ft. 41-1/2” 27-11/16” 20-13/16” 18-5/8” 10-1/4” Side View Front View Bottom View 7-1/8” 5-9/16” 16”...
  • Page 23: Gas Entry Point Dimensions

    GAS ENTRY POINT DIMENSIONS TOP VIEW Finished Wall Fireplace Regulator Gas Entry Point REGULATOR GAS ENTRY POINT Model 3/4” 1-3/4” 4-5/16” Scandium™ (20mm) (45mm) (110mm) Note: The actual dimensions are shown in millimeters. The fractional dimensions are converted from millimeters and are rounded to the nearest 1/16”.
  • Page 24: Product Reference Information

    Fuel Type c Natural Gas c Propane Gas Lennox Hearth Products reserves the right to make changes at any time, without notice, in design, materials, specifications, prices and also to discontinue colors, styles and products . Consult your local distributor for fireplace code information .

This manual is also suitable for:

Scandium-lp

Table of Contents