Lennox Hearth Products X-FIRES-WS-NG Installation And Operation Instructions Manual
Lennox Hearth Products X-FIRES-WS-NG Installation And Operation Instructions Manual

Lennox Hearth Products X-FIRES-WS-NG Installation And Operation Instructions Manual

Catalytic vent-free fireplaces x-fires widescreen models

Advertisement

WHAT'S INSIDE
Table of Contents . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2
Safety and Your Fireplace . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2
FREE Safety Guard Offer
(Protects Against Burns)
Important Safety Information . . . . . . . . . . . . . . . . . . . . . . . . . . 4
L'information de sûreté importante
[EN FRANÇAIS]
Información importante de seguridad
[EN ESPAÑOL]
Manufacturer: Focal Point Fires plc. United Kingdom
This is an unvented gas-fired heater. It uses air
(oxygen) from the room in which it is installed.
Provisions for adequate combustion and ventila-
tion air must be provided. Refer to Combustion
and Ventilation Air section in this manual.
This appliance may be installed in an aftermarket permanently located, manufactured (mobile) home, where not
prohibited by local codes. This appliance is only for use with the type of gas indicated on the rating plate. This appli-
ance is not convertible for use with other gases.
WARNING
• HOT GLASS WILL
CAUSE BURNS.
• DO NOT TOUCH GLASS
UNTIL COOLED.
• NEVER ALLOW CHILDREN
TO TOUCH GLASS.
WARNING: If the information in these instructions is
not followed exactly, a fire or explosion may result
causing property damage, personal injury or death.
- Do not store or use gasoline or other flammable
vapors and liquids in the vicinity of this or any other
appliance.
- WHAT TO DO IF YOU SMELL GAS
• Do not try to light any appliance.
• Do not touch any electrical switch; do not use any
phone in your building.
• Immediately call your gas supplier from a neigh-
bor's phone. Follow the gas supplier's instruc-
tions.
• If you cannot reach your gas supplier, call the fire
department.
- Installation and service must be performed by a
qualified installer, service agency or the gas supplier.
P/N 506023-05 Rev. D 04/2012
. . . . . . . . . . . . . 2
. . . . . . . . . . . . 3–4
. . . . . . . . . . . . 3–4
AVERTISSEMENT
/
• UNE SURFACE VITRÉE CHAUDE PEUT
CAUSER DES BRÛLURES.
• LAISSER REFROIDIR LA SURFACE
VITRÉE AVANT D'Y TOUCHER.
• NE PERMETTEZ JAMAIS À UN ENFANT
DE TOUCHER LA SURFACE VITRÉE.
INSTALLATION AND OPERATION INSTRUCTIONS
Catalytic Vent-Free Fireplaces
X-FIRES™ Widescreen Models
MODELS
X-FIRES WS-NG and X-FIRES WS-LP
Portland
US
OTL Report No. 317-F-11-5
INSTALLER: Leave this manual
with the appliance.
Wait...
DON'T
THROW
IT AWAY!
This manual contains
important operating
and safety
information.
CONSOMMATEUR : Conservez cette
notice pour consultation ultérieure.
AVERTISSEMENT: Assurez-vous de bien suivre les instruc-
tions données dans cette notice pour réduire au minimum
le risque d'incindie ou d'explosion ou pour éviter tout
dommage matériel, toute blessure ou la mort.
- Ne pas entreposer ni utilizer d'essence ni d'autres vapeurs
ou liquides inflammables dans le voisinage de cet appareil
ou de tout autre appareil.
- QUE FAIRE SI VOUS SENTEZ UNE ODEUR DE GAZ:
• Ne pas tenter d'allumer d'appareil.
• Ne touchez à aucan interrupteur. Ne pas vous servir des
téléphones se trouvant dans le bâtiment où vous trouvez.
• Appelez immédiatement votre fournisseur de gaz depuis
un voisin. Suivez les instructions du fournisseur.
• Si vous ne pouvez rejoindre le fournisseur de gaz, appelez
le service des incindies.
- L'installation et l'entretien doivent être assurés par un
installateur ou un service d'entretien qualifié ou par le
fournisseur de gaz.
CONSUMER: Retain this manual
for future reference.
INSTALLATEUR : Laissez cette
notice avec l'appareil.
AVISO
/
• EL VIDRIO CALIENTE
CAUSARÁ QUEMADURAS.
• USTED DEBE NUNCA
TOCAR EL VIDRIO CALIENTE.
• LOS NIÑOS DEBEN NUNCA
TOCAR EL VIDRIO.

Advertisement

Table of Contents
loading

Summary of Contents for Lennox Hearth Products X-FIRES-WS-NG

  • Page 1 INSTALLATION AND OPERATION INSTRUCTIONS Catalytic Vent-Free Fireplaces X-FIRES™ Widescreen Models P/N 506023-05 Rev. D 04/2012 MODELS WHAT'S INSIDE X-FIRES WS-NG and X-FIRES WS-LP Table of Contents . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2 Safety and Your Fireplace .
  • Page 2: Table Of Contents

    To receive your FREE SAFETY GUARD, call 1-800-786-7976  To prevent severe burns and injuries, install or visit www.lennox.com (Lennox Hearth Products / Owner Resources) a screen or physical barrier to prevent direct Note: Safety Guards may not be available for some contact with the glass .
  • Page 3 Toutes les parties de votre foyer ¡Todas las partes de la chimenea Lennox Hearth Products deviennent Lennox Hearth Products se ponen EXTRÊMEMENT CHAUDES ! MUY CALIENTES!  Afin d'éviter de vous brûler gravement ou de  Instale una malla o barrera física para evitar vous blesser, installez une grille ou une barrière...
  • Page 4: Important Safety Information

    Important Safety Information L'information de sûreté importante 1. AVERTISSEMENT. Ne pas utiliser l’appareil si le panneau frontal 1. WARNING: Do not operate appliance with the glass front en verre n’est pas en place, est craqué ou brisé. removed, cracked or broken. 2.
  • Page 5: Appliance Installation, Service, And

    Appliance Installation, Appliance Operation Notices General Information Service, and Maintenance Do not operate appliance with the glass Do not build a wood fire. Do not Notices front removed, cracked, or broken. burn wood or other material in these appliances. These fireplaces are unvented gas WARNING: Improper installation, appliances.
  • Page 6: General Information

    General Information The appliance is designed to fit various types of situations as listed in the installation requirements . WARNING This appliance is factory set for operation on the gas type, and This appliance is equipped for (natural or propane) at the pressure stated on the appliance rating plate .
  • Page 7: Packaging List

    6,820 BTU/hour 6,820 BTU/hour Pilot Energy Input 560 BTU/hour 560 BTU/hour This Lennox Hearth Products Unvented Gas Room Heater is certified by OMNI-Test Laboratories, Inc to ANSI Z21 .11 .2 standard . Main burner flow restrictor 1.55 mm (0.063”) 1.03mm (0.042”)
  • Page 8: Combustion And Ventilation Air

    Example: COMBUSTION AND VENTILATION AIR Vent-free heater #1 9,000 BTU/Hr Vent-free heater #2 23,000 BTU/Hr This heater shall not be installed in a confined space or unusually tight Gas appliance #1 35,000 BTU/Hr construction unless provisions are provided for adequate combustion and (water heater) ventilation air .
  • Page 9: Site Requirements

    CLEARANCES TO COMBUSTIBLE MATERIALS SITE REQUIREMENTS Combustible materials are defined as wood, fabrics, or other materials This appliance is designed to be wall-hung . Do not recess any part of likely to combust if exposed to flame . Generally, any material, which is the appliance into the wall .
  • Page 10: Gas Supply Routes

    GAS SUPPLY ROUTES Wall Mounting Plate IMPORTANT NOTE: All gas piping must be done by a licensed plumber or gas fitter and must conform to the requirements of the National Fuel Gas Code NFPA 54 / ANSI Z223.1 - latest edition. Gas connection: The heater gas inlet connection is 3/8”...
  • Page 11: Mounting The Appliance

    Incorrect installation can cause the appliance to fall from the wall and MOUNTING THE APPLIANCE cause injury . Do not block the ventilation holes of the appliance . The wall onto which the appliance is installed must be flat . Install only on a vertical surface .
  • Page 12: Fitting The Surround Assembly

    It is recommended that the burner height, where possible, should FITTING THE SURROUND ASSEMBLY be approximately 4 ft . from the floor . This will give the best viewing position . When selecting the height, ensure that the clearance to the ceiling is 32"...
  • Page 13: Checking The Burner

    An ANSI approved manual shut-off valve and union must be installed CHECKING THE BURNER upstream of the heater within the fireplace cavity when rigid pipe is used . Ensure that a sediment trap is installed upstream of the heater (Figure 6) within the structure’s piping system to prevent moisture and There are no imitation fuel bed components, such as logs or rocks, contaminants from passing through the pipe to the heater controls and to install .
  • Page 14: 17.0 Gas Pressure Check

    17.0 GAS PRESSURE CHECK SPARK GAP The gap between the spark electrode and the pilot should be 1/8” to The heater regulator controls the burner pressure which should be 3/16” to produce a good spark . There should be no need to adjust this checked at the pressure test point located on the appliance inlet pipe .
  • Page 15: Servicing

    7 . Remove the burner unit, strip off the burner pipes and clean thor- SERVICING oughly . 8 . Clean the in-line restrictor, pilot assembly and the burner tube . Clean the exterior of the pilot assembly with a soft brush and blow through WARNING the flame ports on the pilot head .
  • Page 16: Catalysts

    Turn on the fireplace as per the operating instructions, and run at CATALYSTS maximum setting for 15 minutes . Position gas sample probe directly over a cata lyst via the outlet grill, on top of the appliance . Record the carbon diox ide (CO ) concentration and then the carbon monoxide (CO) WARNING...
  • Page 17: Appliance

    LIGHTING INSTRUCTIONS & TURNING OFF APPLIANCE FOR YOUR SAFETY READ BEFORE LIGHTING WARNING: IF YOU DO NOT FOLLOW THESE INSTRUCTIONS EXACTLY, A FIRE OR EXPLOSION MAY RESULT CAUSING PROPERTY DAMAGE, PERSONAL INJURY OR LOSS OF LIFE. This appliance has a pilot which must be lit with a piezo spark •...
  • Page 18: Troubleshooting Guide

    TROUBLESHOOTING GUIDE PROBLEM CORRECTIVE ACTION Igniter sparks but pilot does not light • No gas to Pilot, check the gas line connections . • Air not fully purged . Purge supply or wait longer . • Spark grounding to metal work, reset gap correctly . •...
  • Page 19: Replacement Parts List

    REPLACEMENT PARTS - X-Fires™ Widescreen POSITION SPIRIT LEVEL ALONG THIS EDGE TO LEVEL TEMPLATE BEFORE MARKING OUT WALL COLOQUE EL NIVEL SOBRE ESTE BORDE PARA NIVELAR LA PLANTILLA ANTES DE MARCAR LA PARED FIXING POINTS PIERCE TEMPLATE TO MARK HOLE POSITION ON WALL X 4 Replacement Parts PUNTOS DE SUJECION PERFORE LA PLANTILLA PARA MARCAR LA POSICION DE LOS 4 TALADROS EN LA PARED...
  • Page 20: Positioning Of Field Assembled Parts

    POSITIONING OF FIELD REMOVABLE PARTS WARNING Failure to position the parts in accordance with these diagrams Glass Door Removal: Remove or failure to use only parts specifi- the four (4) screws indicated, cally approved with this heater then lift door off. may result in property damage or personal injury.
  • Page 21: Accessories

    ACCESSORIES - X-FIRES™ WIDESCREEN SPECIFICATIONS Product Reference Information Cat. No. Model Ship. Wt. Ship. Volume H7224 X-FIRE-WS-NG 71 lb. 6.07 cu. ft. H7225 X-FIRE-WS-LP 71 lb. 6.07 cu. ft. Surround Specifications 54-1/2” 37-13/16” 25-5/8” 21-1/16” 10-5/8” 8-5/8” 5-1/2” 39-15/16” 16” 16”...
  • Page 22: Gas Entry Point Dimensions

    GAS ENTRY POINT DIMENSIONS TOP VIEW Finished Wall Fireplace Regulator Gas Entry Point REGULATOR GAS ENTRY POINT Model 3/8” 1-3/8” 4-5/16” X-fires™ Widescreen (10mm) (35mm) (110mm) Note: The actual dimensions are shown in millimeters. The fractional dimensions are converted from millimeters and are rounded to the nearest 1/16”.
  • Page 23 NOTES...
  • Page 24: Product Reference Information

    Fuel Type c Natural Gas c Propane Gas Lennox Hearth Products reserves the right to make changes at any time, without notice, in design, materials, specifications, prices and also to discontinue colors, styles and products . Consult your local distributor for fireplace code information .

This manual is also suitable for:

X-fires-ws-lp

Table of Contents