Installing the Duct
Outlet side
• Connect the duct according to the inside of the outlet-side flange.
• Wrap the outlet-side flange and the duct connection area with aluminum tape or something similar to prevent air escaping.
CAUTION
• Be sure to insulate the duct to prevent condensation from forming. (Material: glass wool or polyethylene foam, 1 inch (25mm)
thick)
• Use electric insulation between the duct and the wall when using metal ducts to pass metal laths of the net or fence shape or
metal plating into wooden buildings.
Wiring
See the installation manual supplied with the outdoor unit.
HOW TO CONNECT WIRINGS.
• Wire only after removing the control box cover as shown in the Fig.
Control box cover
Wiring Diagram
(rear)
*Remote controller wiring
Lock nut
(field supply)
Conduit
(field supply)
10
Flange
(field supply)
Connection screw
(accessory)
Aluminum tape
(field supply)
Air inlet side
Conduit mounting plate
(accessory)
Screw
(accessory)
Power supply wiring
Ground wire
Main unit
Flange
Aluminum tape
(field supply)
Outlet side
• Wrap the power supply wiring and the remote controller
wiring with the sealing material as shown in the figure
below.
(Otherwise, moisture or small creatures such as insects from
the outside may cause short-circuit inside the control box.)
Attach securely so that there are no gaps.
Insulation material
(field supply)
Sealing material
Wiring
(accessory)
through hole
Wire
Outside
Inside
unit
unit
[How to adhere it]