CTs 2-Channel Power Amplifiers
8 AC Power Draw and Thermal Dissipation
AC Power Draw and Thermal Dissipation:
Pink noise 12dB crest factor, bandwidth limited 22Hz to 22kHz.
Typical line impedance used.
Measurements made with 120VAC mains. Data based on all channels driven.
Line current figures for 230VAC units derived by multiplying 120VAC figures by 0.5.
Line current figures for 100VAC units (not shown) are 1.2 times the line current figures of 120VAC units.
Power draw ("watts in") of 100VAC units is the same as power draw of 120VAC units.
At Idle (sleep mode)
1/8th Power Pink Noise
Typical of program material
just at clip.
1/3rd Power Pink Noise
Typical of program material
with severe clipping.
Operation Manual
Rated
Line Current
Load
Power
8 Ohms/Ch.
1000x2
16 Ohms Bridge
2000
4 Ohms/Ch.
1000x2
8 Ohms Bridge
2000
2 Ohms/Ch.
1000x2
4 Ohms Bridge
2000
70/100V/Ch.
1000x2
140/200V Bridge 2000
8 Ohms/Ch.
1250x2
16 Ohms Bridge
2500
4 Ohms/Ch.
1500x2
8 Ohms Bridge
3000
2 Ohms/Ch.
1500x2
4 Ohms Bridge
3000
70/100V/Ch.
1500x2
140/200V Bridge 3000
CTs 3000
Line Current
120VAC
230VAC
watts in
40
7.2
3.6
579
8.5
4.2
697
9.6
4.8
790
7.2
3.6
579
13.7
6.8
1196
16.2
8.1
1469
19.2
9.6
1686
13.7
6.8
1196
Watts
Thermal Dissipation
watts out
dissapated
Btu/hr
0
40
137
313
266
907
381
316
1079
384
405
1384
313
266
907
835
360
1230
1010
459
1565
1024
662
2259
835
360
1230
kcal/hr
34
229
272
349
229
310
395
570
310
page 27