8 AC Power Draw and Thermal Dissipation
AC Power Draw and Thermal Dissipation:
Pink noise 12dB crest factor, bandwidth limited 22Hz to 22kHz.
Typical line impedance used.
Measurements made with 120VAC mains. Data based on all channels driven.
Line current figures for 230VAC units derived by multiplying 120VAC figures by 0.5.
Line current figures for 100VAC units (not shown) are 1.2 times the line current figures of 120VAC units.
Power draw ("watts in") of 100VAC units is the same as power draw of 120VAC units.
At Idle (sleep mode)
1/8th Power Pink Noise
Typical of program material
just at clip.
1/3rd Power Pink Noise
Typical of program material
with severe clipping.
page 26
Rated
Line Current
Load
Power
8 Ohms/Ch.
1000x2
16 Ohms Bridge
2000
4 Ohms/Ch.
1000x2
8 Ohms Bridge
2000
2 Ohms/Ch.
1000x2
4 Ohms Bridge
2000
70/100V/Ch.
1000x2
140/200V Bridge 2000
8 Ohms/Ch.
1000x2
16 Ohms Bridge
2000
4 Ohms/Ch.
1000x2
8 Ohms Bridge
2000
2 Ohms/Ch.
1000x2
4 Ohms Bridge
2000
70/100V/Ch.
1000x2
140/200V Bridge 2000
CTs 2000
Line Current
120VAC
230VAC
watts in
40
6.6
3.3
546
7.0
3.5
563
7.2
3.6
602
6.7
3.4
639
11.3
5.6
980
12.3
6.2
1064
13.7
6.9
1190
11.6
5.8
990
CTs 2-Channel Power Amplifiers
Watts
Thermal Dissipation
watts out
dissapated
Btu/hr
0
40
137
256
290
988
255
307
1049
251
351
1198
257
382
1304
676
304
1036
672
392
1338
705
485
1655
674
316
1080
Operation Manual
kcal/hr
34
249
264
302
329
261
337
417
272