CTs 2-Channel Power Amplifiers
6 Troubleshooting
Operation Manual
CONDITION: No sound, even though
the amp has power. Power LED is on with-
out flashing and the amp is receiving an input sig-
nal. Signal indicator is flashing.
POSSIBLE REASON:
Speakers not connected.
Open circuit due to speaker failure.
There is a short on the amplifier output. First
disconnect your speakers from the affected
channel(s) one by one to determine if one of
the loads is shorted.
Ready LED is off. Channel has been set to
standby mode via the IQ system.
CONDITION: No input signal. Signal
indicator is not flashing even though audio is
applied, and the channel is ready..
POSSIBLE REASON:
Input signal level is very low.
Level controls are turned down.
CONDITION: Data indicator not flash-
ing, even though PIP module is
installed and host computer IQ soft-
ware is active.
POSSIBLE REASON:
Cable between computer and PIP module is
broken or not connected.
Note: Data indicator flashes only when the installed
PIP2 module is polled for data, or is polled to see
whether it is online.
"Off/Flashing/On" above means that
the LED can be off, or flashing, or on.
page 19