Nominal Attenuation Settings - Crown CTs 1200 Operation Manual

Cts 2-channel series
Hide thumbs Also See for CTs 1200:
Table of Contents

Advertisement

CTs 2-Channel Power Amplifiers
5 Advanced Features
and Options

5.3.1 Nominal Attenuation Settings

The signal level for each input can be attenuated accurately by
adjusting the 21-step Level Control (see Section 4.3). Figure 5.5
shows the attenuation in dB for each detent. The setting of the
input-sensitivity switch varies the actual attenation as shown.
The accuracy of the attenuation varies with the setting. Expected
tolerances are:
Potentiometer steps 0-6 dB: ± 1 dB
Potentiometer steps 6-12 dB: ± 1.5 dB
Potentiometer steps 12-24 dB: ± 3 dB
Potentiometer steps 24-54 dB: ± 6 dB
Operation Manual
Detent
26 dB
0 (full CW)
0.0
1
0.5
2
1.0
3
2.0
4
3.0
5
4.0
6
5.0
7
6.0
8
7.0
9
8.0
10
9.0
11
10.5
12
12.0
13
13.5
14
15.0
15
18.0
16
21.0
17
24.0
18
36.0
19
48.0
20 (full CCW)
OFF
Figure 5.5 Attenuation vs. Detent of Level Controls for CTs 2-Channel Amplifiers
4/8 ohm or 70/100V
0.0
0.5
1.5
3.5
5.0
6.5
8.0
9.5
11.0
13.0
14.5
16.0
18.0
20.0
22.0
24.0
26.0
30.0
42.0
54.0
OFF
page 17

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Cts 600Cts 2000Cts 30001200Cts series

Table of Contents