Download Print this page

Crown CTS3000 Ac Power Draw And Thermal Dissipation

Crown cts3000: specifications
Hide thumbs Also See for CTS3000:

Advertisement

Quick Links

AC Power Draw and Thermal Dissipation:

Pink noise 12dB crest factor, bandwidth limited 22Hz to 22kHz.
Typical line impedance used.
Measurements made with 120VAC mains. Line current figures for 230VAC units derived by multiplying 120VAC figures by 0.5.
Data based on all channels driven.
At Idle (sleep mode)
1/8th Power Pink Noise
8 Ohms/Ch.
16 Ohms Bridge
Typical of program material
4 Ohms/Ch.
just at clip.
8 Ohms Bridge
2 Ohms/Ch.
4 Ohms Bridge
70/100V/Ch.
140/200V Bridge 2000
1/3rd Power Pink Noise
8 Ohms/Ch.
16 Ohms Bridge
Typical of program material
4 Ohms/Ch.
with severe clipping.
8 Ohms Bridge
2 Ohms/Ch.
4 Ohms Bridge
70/100V/Ch.
140/200V Bridge 3000
Rated
Line Current
Load
Power
120VAC
1000x2
7.2
2000
1000x2
8.5
2000
1000x2
9.6
2000
1000x2
7.2
1250x2
13.7
2500
1500x2
16.2
3000
1500x2
19.2
3000
1500x2
13.7
CTs 3000
Line Current
230VAC
watts in
40
3.6
579
4.2
697
4.8
790
3.6
579
6.8
1196
8.1
1469
9.6
1686
6.8
1196
Watts
Thermal Dissipation
watts out
dissapated
Btu/hr
0
40
137
313
266
907
381
316
1079
384
405
1384
313
266
907
835
360
1230
1010
459
1565
1024
662
2259
835
360
1230
kcal/hr
34
229
272
349
229
310
395
570
310

Advertisement