Download Print this page
Crown CTS2000 Ac Power Draw And Thermal Dissipation

Crown CTS2000 Ac Power Draw And Thermal Dissipation

Crown cts2000: specifications
Hide thumbs Also See for CTS2000:

Advertisement

AC Power Draw and Thermal Dissipation:

Pink noise 12dB crest factor, bandwidth limited 22Hz to 22kHz.
Typical line impedance used.
Measurements made with 120VAC mains. Line current figures for 230VAC units derived by multiplying 120VAC figures by 0.5.
Data based on all channels driven.
At Idle (sleep mode)
1/8th Power Pink Noise
8 Ohms/Ch.
16 Ohms Bridge
Typical of program material
4 Ohms/Ch.
just at clip.
8 Ohms Bridge
2 Ohms/Ch.
4 Ohms Bridge
70/100V/Ch.
140/200V Bridge 2000
1/3rd Power Pink Noise
8 Ohms/Ch.
16 Ohms Bridge
Typical of program material
4 Ohms/Ch.
with severe clipping.
8 Ohms Bridge
2 Ohms/Ch.
4 Ohms Bridge
70/100V/Ch.
140/200V Bridge 2000
Rated
Line Current
Load
Power
120VAC
1000x2
6.6
2000
1000x2
7.0
2000
1000x2
7.2
2000
1000x2
6.7
1000x2
11.3
2000
1000x2
12.3
2000
1000x2
13.7
2000
1000x2
11.6
CTs 2000
Line Current
230VAC
watts in
40
3.3
546
3.5
563
3.6
602
3.4
639
5.6
980
6.2
1064
6.9
1190
5.8
990
Watts
Thermal Dissipation
watts out
dissapated
Btu/hr
0
40
137
256
290
988
255
307
1049
251
351
1198
257
382
1304
676
304
1036
672
392
1338
705
485
1655
674
316
1080
kcal/hr
34
249
264
302
329
261
337
417
272