Mic/line mixers
Hide thumbs Also See for 301:

Advertisement

Remote Control: When using a slide potentiometer as a remote control, wire with High (T) to the voltage terminal ('V'), Wiper (W) to the
control terminal ("C"), and Low (B) to the ground terminal (' '). When using a rotary potentiometer, wire with High (CW) to the voltage
terminal ("V"), Wiper (W) to the control terminal ("C"), and Low (CCW) to the ground terminal (" "). Potentiometers should be linear taper,
of any value from 5k ohms to 50k ohms, and may be wired up to 2000 feet from the mixer. Cable should be 2-conductor with shield. A
remote level control wall-plate, model RP-L1, is available. If an on/off switch is utilized, "ON" position should connect the voltage terminal
('V") to the control terminal ("C"). Different wiring techniques, using both a potentiometer and a switch, can provide either level and mute
functions or adjustable muting attenuation.
NOTE: The rear panel Remote Enable switch must be depressed for remote controls to function (see Enable Switches on page 3).
+10V C
gnd

REMOTE CONTROL

REMOTE CONTROL WIRING DIAGRAM
toggle
off
switch
on
4
rotary
pot.
w
ccw
cw
slide
T
pot.
W
B