Regulation, Standard And Guidesline - AEG ARCTIS 65240 GA User Manual

Aeg freezer
Hide thumbs Also See for ARCTIS 65240 GA:
Table of Contents

Advertisement

Available languages

Available languages

Malfunction
Heavy build up of frost, possi-
bly also on the door seal.
Unusual noises.
The compressor does not start
immediately after changing
the temperature setting.
Regulations, Standards, Guidelines
This appliance was designed for household use and was manufactured in
accordance with the appropriate standards. The necessary measures in
accordance with appliance safety legislation regulations (GSG), accident
prevention regulations for refrigeration appliances (VBG 20) and the regu-
lations of the German Society of Electrical Engineers (VDE) were observed in
the manufacture of this appliance.
The refrigerant circuit has been checked for leaks.
This appliance is in accordance with the following EU guidelines:
– 73/23/EWG dated 19 February 1973 - low voltage guidelines.
– 89/336/EWG dated 3 May 1989
(including guideline change notice 92/31/EWG) - EMV guideline
70
Possible Cause
Door seal is not air tight (pos-
sibly after changing over the
hinges).
Appliance is not level.
The appliance is touching the
wall or other objects.
A component, e.g. a pipe, on
the rear of the appliance is
touching another part of the
appliance or the wall.
This is normal, no error has
occurred.
Remedy
Carefully warm the leaking
sections of the door seal with
a hair dryer (not hotter than
approx. 50 °C). At the same
time shape the warmed door
seal by hand such that it sits
correctly.
Readjust the feet.
Move the appliance slightly.
If necessary, carefully bend
the component out of the
way.
The compressor starts after a
period of time.

Hide quick links:

Advertisement

Table of Contents
loading