Installation - Electrolux EFC9588X Installation And User Manual

Electrolux range hood
Table of Contents

Advertisement

Installation

Installation sequence
1 Using a spirit level mark a vertical centre line on the wall
where the hood is to be positioned, and a horizontal line
at the hood base position (refer diagram bottom left).
NOTE: The height of the underside of the hood body must
be a minimum of 550mm above an electric cooktop
& gas cook top and a maximum height of 750mm
(refer to table).
* I
f the instructions of the hob specify a greater distance than the minimum
above, then that shall be the minimum height for installation.
2 M ark the location for the wall and ceiling fixing points
above the hood base using the hood base as the
reference point.
3 Install wall and ceiling mounting with suitable screws
(to support a total weight of 30kg) to the wall at the
positions marked in diagram.
4 Remove the protective plastic film from the hood body
and hang hood on the mounting points then secure at
the anti-tilt locations as indicated in diagram.
Depending on the preferred installation/ducting mode,
follow step 5a or 5b below.
5a Recirculating mode (Fig. A, previous page). Using the
centre line, secure the mount bracket to the wall using
suitable screws. Attach the recirculating T-piece. Use
cable ties or suitable duct tape to secure the T-piece.
NOTE: When installed in recirculation mode, it is
recommended to use a carbon filter (included as
standard equipment with EFC9588X).
OR
5b Ducted mode (Fig. B, previous page). The range hood
has been supplied with flexible exhaust pipe and duct
transition piece, alternatively a 150mm diameter non-
combustible flue pipe can be used. Continue the centre
line to the ceiling. Attach the ceiling mount bracket on
the centre line. Fit preferred flue pipe to the fan
transition duct.
30 (from ceiling)
100
All lines are to the
centres of the holes
250
398
200
220
240
200
100
90
250
108
23
200
220
240
electrolux rangehood dimensions/installation 5
NOTE: The fan housing exhaust outlet is 163mm in
diameter. Use duct transition or flexible pipe supplied
with the rangehood as a reducer if using 150mm
optional ducting accessories.
NOTE: For ducted mode, we recommend extending flue
pipe through the roof to external "china hat" to vent
exhaust externally. We do not recommend venting
into ceiling cavity.
NOTE: To ensure optimum performance of the rangehood,
the use of rigid ducting is recommended. The use
of bends should be avoided. Rigid flexible ducting
is suitable, although loose flexible ducting is
unacceptable. All ducting must be fire retardant.
Installation of telescopic exhaust covers
Separate the inner and outer exhaust covers, and carefully
remove the protective coating from both. Carefully
reassemble the inner and outer exhaust covers sections by
sliding the inner into the outer exhaust cover. Carefully lower
the assembled inner and outer exhaust covers onto the
top of the cooker hood body, and insert the exhaust cover
into the rangehood body approximately 5mm. Fix inner
(top) exhaust cover to the mounting bracket with screws
supplied. Ensure that the inner (top) section is extended.
important
Care must be taken to ensure the screws are not cross
threaded when attaching the outer flue cover.
If installed in recirculating mode, insert the carbon filter.
To complete the rangehood installation, replace the filter.
Place back edge of filter into position and push up front
edge so that the filter clips into place.
Your Electrolux rangehood is now ready to use.