Regulating The Minimum Flame - Candy PG750 User Instructions

Table of Contents

Advertisement

Table of gas consumption
G30
G20/G25
G31
Working
Ø gas jet
Ø gas jet
burner
1/100 mm
1/100 mm
large
120
80
medium
93
61
maxi
2x94
2x65
double ring
2x94
2x65
fish
2x94
2x65
SETTING OF THE GAS BURNERS
When the jets have been changed it is necessary to set the correct air gap by keeping
to the setting "X" as shown in the table " gas consumption" fig 7. Warning the value of '
X ' setting varies in relation to the size of gas burner and type of gas chosen.
A good flame must be of medium length (fig.8B), excessive air will cause the flame to
be short and with sharp colour (fig.8C): in this case it is necessary to extend out the tu-
be for the air setting from the burner body, if there is insufficient air the flame will ap-
pear weak and long (fig. 8A): in this case push the tube of the air setting back into the
burner body. To adjust the air setting tube loosen the retaining screw.
Once the air is correctly set secure the screw over the tube ( fig. 7).
For dimensions «X» see table of gas consumption
BURNER
BURNER CAP
AIR REGULATION
SCREW

REGULATING THE MINIMUM FLAME

After lighting the burners, turn the control knob to the minimum setting and then remo-
ve the knob (this can easily be removed by apply a gentle pressure).
Using a small «Terminal» type screwdriver the regulating screw can be adjusted as in
Fig. 9. Turning the screw clockwise reduces the gas flow, whilst turning it anticlockwise
increases the flow – Use this adjustment to obtain a flame of approximately 3 to 4 mm
in length and then replace the control knob.
When the gas supply available is LPG (Bottle gas)- the screw to set the idle flame must
be turned (clockwise) to the end stop.
Screws regulating
Fig. 9
IE
GB
G20 20mbar
G30 29mbar
G31 37mbar
g/h
STD. Dim
l/h
g/h
G31
kW
G20
G30
189
2,65
252
193
107
1,5
143
109
236
3,3
314
238
236
3,3
314
238
236
3,3
314
238
SMALL
MEDIUM
LARGE
FIXING
SCREW
DOUBLE RING
MAXI
Fig. 7
FISH
(for differend models)
45
X dimension according
1W = 0,860 kcal/h
G25
G20
25mbar
Qn
l/h
min.Dim
reg.
kW
G25
kW
air
2,5
277
0,65
4 mm
1,45
161
0,38
2 mm
3,1
343
0,9
15 mm
3,1
343
0,9
13 mm
3,1
343
0,9
15 mm
to Gas type
G30
G25
G31
reg.
reg.
reg.
air
air
air
2 mm
4 mm
5 mm
5 mm
2 mm
7 mm
0 mm
15 mm
15 mm
0 mm
13 mm
15 mm
15 mm
15 mm
0 mm
Fig. 8