1. Prior to initial operation, add oil to the crank- case so that oil level is between the two lines on the oil dipstick. DO NOT OVERFILL. Use Giant oil or a synthetic oil such as Mobil 1 (15W-50). Crankcase oil should be changed after the...
Volume ... Up to 3.4 GPM Discharge Pressure ... Up to 2500 PSI* Inlet Pressure ... Up to 90 PSI RPM ... Up to 3450 RPM Plunger Diameter... 18mm Stroke ... 5.5mm Temperature of Pumped Fluids ... Up to 160 Inlet Ports ...
Page 4
Volume ... Up to 3.4 GPM Discharge Pressure ... Up to 2500 PSI* Inlet Pressure ... Up to 90 PSI RPM ... Up to 1750 RPM Plunger Diameter... 18mm Stroke ... 10.0mm Temperature of Pumped Fluids ... Up to 160 Inlet Ports ...
Page 5
Volume ... Up to 4.2 GPM Discharge Pressure ... Up to 2500 PSI* Inlet Pressure ... Up to 90 PSI RPM ... Up to 1750 RPM Plunger Diameter ... 18mm Stroke ... 12.4mm Temperature of Pumped Fluids ... Up to 160 Inlet Ports ...
Page 6
Volume ... Up to 4.7GPM Discharge Pressure ... Up to 2000 PSI Inlet Pressure ... Up to 90 PSI RPM ... Up to 1750 RPM Plunger Diameter ... 18mm Stroke ... 14.1mm Temperature of Pumped Fluids ... Up to 160 Inlet Ports ...
Page 7
Volume ... Up to 2.21 GPM Discharge Pressure ... Up to 2500 PSI* Inlet Pressure ... Up to 90 PSI RPM ... Up to 1750 RPM Plunger Diameter... 18mm Stroke ... 7.0mm Temperature of Pumped Fluids ... Up to 160 Inlet Ports ...
Page 8
Volume ... Up to 3.0 GPM Discharge Pressure ... Up to 3000 PSI* Inlet Pressure ... Up to 90 PSI RPM ... Up to 3450 RPM Plunger Diameter... 16mm Stroke ... 6.3mm Temperature of Pumped Fluids ... Up to 160 Inlet Ports ...
P200A SERIES PARTS LIST ITEM PART NO. DESCRIPTION 08300 Crankcase 08301 Dipstick and Gasket, Black (Except P217& P223) 08480 Dipstick and Gasket, Red (P217& P223) 08302 Crankcase Cover, Short 08302-L Crancase Cover, Long 07190 Drain Plug & Gasket 08005 O-Ring...
REPAIR INSTRUCTIONS - P200A SERIES NOTE: Always take time to lubricate all metal and nonmetal parts with a light film of oil before reassembly. This step will ensure proper fit, at the same time protecting the pump nonmetal parts (i.e., the elastomers) from cutting and scoring.
Page 13
( 33). For pumps manufactured prior to 5/97, tighten plugs (32) to 33 ft-lbs. otherwise, apply one drop of Loctite 243 to the valve plugs (32) and tighten to 59 ft.-lbs. For maintenance of the gear end of your pump contact Giant Industries or your local distributor. Phone: 419/531-4600 NOTE: Contact Giant Industries for Service School Information.
Page 16
A Returned Goods Authorization (R.G.A.) number and completed warranty evaluation form is required prior to the return to Giant Industries of all products under warranty consideration. Call (419)-531-4600 or fax (419)-531-6836 to obtain an R.G.A.