Giant P217 Operating Instructions/ Repair And Service Manual

Giant P217 Operating Instructions/ Repair And Service Manual

Triplex ceramic plunger pump p200a series

Advertisement

Series
P200A
Updated 6/00
Triplex Ceramic
Plunger Pump
Operating Instructions/
Repair and Service
Manual
For Models:
P217
P218
P219
P220
P221
P223
Contents:
Warranty Information:
page 2
pages 3-8
page 9
page 10
pages 12-13
page 14
page 15
back page

Advertisement

Table of Contents
loading

Summary of Contents for Giant P217

  • Page 1: Table Of Contents

    Series P200A Updated 6/00 Plunger Pump Operating Instructions/ Repair and Service Manual For Models: P217 P218 P219 P220 P221 P223 Contents: Installation Instructions: page 2 Pump Specifications: pages 3-8 Parts List: page 9 Exploded View: page 10 Kits & Torque Specifications: page 11...
  • Page 2: Installation Instructions

    1. Prior to initial operation, add oil to the crank- case so that oil level is between the two lines on the oil dipstick. DO NOT OVERFILL. Use Giant oil or a synthetic oil such as Mobil 1 (15W-50). Crankcase oil should be changed after the...
  • Page 3: Pump Specifications: Pages

    Volume ... Up to 3.4 GPM Discharge Pressure ... Up to 2500 PSI* Inlet Pressure ... Up to 90 PSI RPM ... Up to 3450 RPM Plunger Diameter... 18mm Stroke ... 5.5mm Temperature of Pumped Fluids ... Up to 160 Inlet Ports ...
  • Page 4 Volume ... Up to 3.4 GPM Discharge Pressure ... Up to 2500 PSI* Inlet Pressure ... Up to 90 PSI RPM ... Up to 1750 RPM Plunger Diameter... 18mm Stroke ... 10.0mm Temperature of Pumped Fluids ... Up to 160 Inlet Ports ...
  • Page 5 Volume ... Up to 4.2 GPM Discharge Pressure ... Up to 2500 PSI* Inlet Pressure ... Up to 90 PSI RPM ... Up to 1750 RPM Plunger Diameter ... 18mm Stroke ... 12.4mm Temperature of Pumped Fluids ... Up to 160 Inlet Ports ...
  • Page 6 Volume ... Up to 4.7GPM Discharge Pressure ... Up to 2000 PSI Inlet Pressure ... Up to 90 PSI RPM ... Up to 1750 RPM Plunger Diameter ... 18mm Stroke ... 14.1mm Temperature of Pumped Fluids ... Up to 160 Inlet Ports ...
  • Page 7 Volume ... Up to 2.21 GPM Discharge Pressure ... Up to 2500 PSI* Inlet Pressure ... Up to 90 PSI RPM ... Up to 1750 RPM Plunger Diameter... 18mm Stroke ... 7.0mm Temperature of Pumped Fluids ... Up to 160 Inlet Ports ...
  • Page 8 Volume ... Up to 3.0 GPM Discharge Pressure ... Up to 3000 PSI* Inlet Pressure ... Up to 90 PSI RPM ... Up to 3450 RPM Plunger Diameter... 16mm Stroke ... 6.3mm Temperature of Pumped Fluids ... Up to 160 Inlet Ports ...
  • Page 9: Parts List

    P200A SERIES PARTS LIST ITEM PART NO. DESCRIPTION 08300 Crankcase 08301 Dipstick and Gasket, Black (Except P217& P223) 08480 Dipstick and Gasket, Red (P217& P223) 08302 Crankcase Cover, Short 08302-L Crancase Cover, Long 07190 Drain Plug & Gasket 08005 O-Ring...
  • Page 10: Exploded View

    Exploded View - P200A Series...
  • Page 11: Kits & Torque Specifications

    Plunger Packing Kit Part # 09164 (Excluding P223) Item # Qty. Part # Description 08477 V-Sleeve, weep 08087 V-Sleeve, brown 07904 Pressure Ring Plunger Packing Kit Part #09525 (P223 Only) Item # Qty. Part # 06315 06920 Teflon Plunger Packing Kit Part # 09164-0020 (Excluding P223) Item # Qty.
  • Page 12: Repair Instructions: Pages

    REPAIR INSTRUCTIONS - P200A SERIES NOTE: Always take time to lubricate all metal and nonmetal parts with a light film of oil before reassembly. This step will ensure proper fit, at the same time protecting the pump nonmetal parts (i.e., the elastomers) from cutting and scoring.
  • Page 13 ( 33). For pumps manufactured prior to 5/97, tighten plugs (32) to 33 ft-lbs. otherwise, apply one drop of Loctite 243 to the valve plugs (32) and tighten to 59 ft.-lbs. For maintenance of the gear end of your pump contact Giant Industries or your local distributor. Phone: 419/531-4600 NOTE: Contact Giant Industries for Service School Information.
  • Page 14: Trouble Shooting

    Check inlet lines for restrictions and/or proper size Re-size discharge plumbing to flow rate of pump Replace plungers Adjust or Replace packing seals Reduce suction vacuum Replace plungers Reduce inlet pressure Giant oil is recommended Adjust oil level to proper amount...
  • Page 15: Notes & Dimensions

    P200A DIMENSIONS (inches) NOTES...
  • Page 16 A Returned Goods Authorization (R.G.A.) number and completed warranty evaluation form is required prior to the return to Giant Industries of all products under warranty consideration. Call (419)-531-4600 or fax (419)-531-6836 to obtain an R.G.A.

This manual is also suitable for:

P218P219P220P223P221P217a ... Show all